DAK Americas Laser+ 7000 User Manual
Laser
Laser+
®
7000 (B92A)
Product Information
polyethylene terephthalate resin
DAK Americas LLC
Gateway Corporate Center, Suite 210
223 Wilmington W Chester Pike• Chadds Ford, PA 19317
1-888-738-
2002 • fax: 610-558-7385 • www.dakamericas.com
PDS-B92A 140303KH
DAK Americas
ISO 9001:2008
#10004457
Product Description
Laser+
®
7000 (B92A) polyethylene terephthalate (PET) resin is a copolymer formulated for conversion
to PET bottles by conventional single or two-stage processing technology.
Typical Properties
Bi-orientation of Laser+
®
7000 (B92A) by injection/stretch blow molding provides optimal barrier and
mechanical properties, including superior stress crack resistance. It performs exceptionally well in the
manufacture of CSD bottles made from thick-wall preforms, where heatup rate and temperature profile
through the wall are important. DAK has reengineered Laser+
®
7000 (B92A), improving acetaldehyde
(AA) performance without sacrificing intrinsic viscosity (IV), to meet increasing demand for CSD
applications. Laser+
®
7000 (B92A) offers superior heat absorption and processing control, even at
higher blowing speeds. A slower crystallization rate enables high injection molding output.
Certification
Laser+
®
7000 (B92A) is ideally suited for food packaging applications and is considered in compliance
with the Food and Drug Administration (FDA) Food Contact Notification (FCN) 000635, and Health
Canada Health Products and Food Branch (HPFB) file KS 06111304 for PET polymers.
Sales Specifications
Property
Value
Unit
Test Method
Intrinsic Viscosity
0.84 ± 0.02
dL/g
DAK-QAR-SOP-0012
Color L*
67 min
CIE
DAK-QAR-SOP-0011
Color b*
- 4.5 ± 1.4
CIE
DAK-QAR-SOP-0011
Acetaldehyde
2 max
ppm
DAK-QAR-SOP-0010
Moisture Content (as packaged)
0.25 max
weight % DAK-QAR-SOP-0013
Fines (as packaged, +24 Mesh Size)
0.050 max weight % DAK-QAR-SOP-0014
Chip Size, nominal
30
chips / g DAK-QAR-SOP-0015
Crystallinity
> 35
%
DAK-QAR-SOP-0016
Partical Size, Shape (Spherical)
3.5
mm
DAK-QAR-SOP-0017
Melting Point, nominal
242
ºC
DAK-QAR-SOP-0016
Bulk Density
52
lb / ft³
DAK-QAR-SOP-0018
These values represent the anticipated performance data for these polyester resins and intermediates; they are not intended to
be used as design data. We believe this information is the best currently available on the subject. It is offered as a possible
helpful suggestion in the experimentation you may care to undertake along these lines. It is subject to revision as additional
knowledge and experience is gained. DAK Resins makes no guarantee of results and assumes no obligation or liability
whatsoever in connection with this information. This publication is not a license to operate under, or intended to suggest
infringement of, any existing patents.
CAUTION: Do not use in medical applications involving permanent implantation in the human body. For other medical
applications, see “DAK Medical Caution Statement”.