Connection for the auto time adjustment function, Connection of the control output – Panasonic WJ-NV200 - User Manual
Page 27
27
Connection for the auto time adjustment function
When a signal output from the other device is supplied to the time adjustment signal input (pin no. 20) and the time difference
between the recorder and the other device is 29 minutes or less, the clock of the recorder will be set to the time set for the other
device.
When a signal output is supplied to the recorder 29 minutes before/after the hour, the clock of the recorder will be set to the hour
(nn:00:00). ("nn" is the hour.)
Example:
• Signal is supplied at 2:50:00 pm → Set at 3:00:00 pm
• Signal input supplied at 3:28:45 pm → Set at 3:00:00 pm
• Signal is supplied at 3:29:30 pm → Time will not be adjusted.
Note:
• When adjusting the time using the time adjustment signal input, select "On" for "Auto time adjustment". (☞ Page 42)
Connection of the control output
When an alarm device such as a buzzer or a lamp is connected, the signal output from pin no. 20 and pin nos. 15 - 19 can be
used to notify the status by sounding a buzzer or lighting a lamp.
The connection example of the HDD error output (pin no. 16) is as follows.
13
20
Signal gr
ound
Sensor signal input
Alarm input
Alarm r
eset input
Series r
ecor
ding output
Time adjustment signal input
Signal gr
ound
Alarm output
Alarm r
eset output
Alarm r
ecor
ding
During r
ecor
ding
Disk
Buzzer output
System err
or output
Thermal err
or output
Time adjustment signal output
Series r
ecor
ding output
Output for the
indicators on
the front panel
Terminal of the other device
ALARM/CONTROL
(Signal ground)
(Time adjustment signal input)
13
16
(Signal ground)
(HDD error output)
ALARM/CONTROL
Alarming device
* Attached when necessary
Relays, etc.*