beautypg.com

Panasonic KS12NB41A User Manual

Page 56

background image

(3-2) Condition: E12

Troubleshooting Serial Communication

1. Turn off the power and wait until the power lamp (LED)
of the outdoor unit controller is turned OFF.
2. Disconnect the cable from the terminal 3 on the indoor
unit terminal strip. (Fig. 7)

Defect in the indoor unit

P.C. board

Defect in the outdoor unit

P.C. board

1. Turn ON the power and operate the system using the
remote controller or the operation button on the indoor unit.
2. Perform the self-diagnosis five seconds after the operation
start.

1. Turn off the power and wait until the power lamp (LED)
of the outdoor unit controller is turned OFF.
2. Disconnect the cable from the terminal 3 on the Outdoor
unit terminal strip. (Fig. 6)

Defect in the inter-unit

cable

1. Turn ON the power and operate the system using the
remote controller or the operation button on the indoor unit.
2. Perform the self-diagnosis five seconds after the operation
start.

Condition: E12

Condition: E01

Condition: E01

Condition: E12

What is the latest self-diagnosis result ?

What is the latest self-diagnosis result ?

1

2

4

3

5

6

1

2

3

Outdoor Unit

Fig. 6

Power

Indoor Unit

1

2

4

3

5

6

1

2

3

Power

Fig. 7

Outdoor Unit

Indoor Unit

56