3-4. remove the indoor air temperature sensor, 3-5. remove the power box and control box – Panasonic KS12NB41A User Manual
Page 43
1
2
3
7-3-4. Remove the indoor air temperature sensor.
(1) Disconnect the connector CN08 (ROOM 2P) in the control box and remove the indoor air temperature
sensor. (Fig. 10)
7-3-5. Remove the power box and control box.
(1) Remove a screw and remove the terminal cover. (Fig. 11)
(2) Remove the 2 screws and remove the power box cover. (Fig. 11)
(3) Disconnect the power lines (No. 1 and No. 2) / signal line (No. 3) and ground cable from the terminals in
the power box. (Fig. 12)
Indoor air temperature sensor
CN08
Terminal
Fig.10
Fig.11
Fig.12
Ground cable
Terminal cover
Screw
Screw
Power box cover
Power lines / Signal line