Panasonic KS12NB41A User Manual
Page 33
Indoor Unit
: CS-KS18NB4UW & CZ-18BT1U
Outdoor Unit : CU-KS18NKUA
Power Supply : 230V Single Phase 60Hz
< Cooling Capacity (Low Ambient) >
RATING CAPACITY:
17,500 BTU/h
AIR FLOW RATE:
341 CFM
INDOOR
OUTDOOR
ENT. TEMP.
o
F (
o
C)
AMBIENT TEMP.
o
F (
o
C)
WB
DB
0
5
15
25
35
45
55
(-17.8)
(-15.0)
(-9.4)
(-3.9)
(1.7)
(7.2)
(12.8)
TC
13,400
13,430
13,440
13,470
13,500
13,520
13,510
CI
0.69
0.73
0.76
0.66
0.66
0.66
0.70
72 (22.2)
SHC
9,740
9,740
9,740
11,860
9,740
9,800
9,800
59
76 (24.4)
SHC
10,930
10,930
10,930
13,050
11,000
11,000
11,000
(15.0)
80 (26.7)
SHC
12,190
12,190
12,190
13,470
12,190
12,260
12,190
84 (28.9)
SHC
13,380
13,380
13,380
13,470
13,380
13,450
13,450
88 (31.1)
SHC
13,400
13,430
13,440
13,470
13,500
13,520
13,510
TC
13,260
13,300
13,370
13,480
13,560
13,640
13,670
CI
0.78
0.82
0.84
0.71
0.70
0.69
0.72
72 (22.2)
SHC
7,950
7,950
7,950
11,860
8,080
8,080
8,140
63
76 (24.4)
SHC
9,140
9,140
9,210
13,050
9,270
9,270
9,340
(17.2)
80 (26.7)
SHC
10,400
10,400
10,400
13,480
10,530
10,530
10,600
84 (28.9)
SHC
11,590
11,590
11,590
13,480
11,720
11,720
11,790
88 (31.1)
SHC
12,790
12,790
12,850
13,480
12,920
12,980
12,980
TC
12,980
13,040
13,170
13,380
13,530
13,670
13,760
CI
0.89
0.92
0.93
0.78
0.75
0.72
0.75
72 (22.2)
SHC
6,090
6,160
6,220
11,860
6,360
6,420
6,420
67
76 (24.4)
SHC
7,280
7,350
7,420
13,050
7,550
7,610
7,680
(19.4)
80 (26.7)
SHC
8,540
8,610
8,680
13,380
8,810
8,870
8,870
84 (28.9)
SHC
9,740
9,800
9,870
13,380
10,000
10,070
10,070
88 (31.1)
SHC
11,000
11,000
11,060
13,380
11,190
11,260
11,330
TC
12,550
12,630
12,830
13,160
13,390
13,600
13,750
CI
1.00
1.03
1.03
0.85
0.80
0.76
0.77
72 (22.2)
SHC
4,230
4,230
4,370
11,860
4,570
4,630
4,700
71
76 (24.4)
SHC
5,430
5,490
5,560
13,050
5,760
5,820
5,890
(21.7)
80 (26.7)
SHC
6,690
6,690
6,820
13,160
7,020
7,080
7,150
84 (28.9)
SHC
7,880
7,950
8,010
13,160
8,210
8,280
8,340
88 (31.1)
SHC
9,070
9,140
9,210
13,160
9,400
9,470
9,540
TC
12,010
12,110
12,380
12,850
13,150
13,440
13,650
CI
1.11
1.14
1.13
0.92
0.86
0.80
0.80
75
76 (24.4)
SHC
3,640
3,700
3,770
12,850
4,030
4,170
4,230
(23.9)
80 (26.7)
SHC
4,900
4,960
5,030
12,850
5,290
5,360
5,490
84 (28.9)
SHC
6,090
6,160
6,220
12,850
6,490
6,620
6,690
88 (31.1)
SHC
7,280
7,350
7,420
12,850
7,680
7,810
7,880
TC : Total Cooling Capacity (BTU/h) SHC : Sensible Heat Capacity (BTU/h)
1.
2. Above data represents the value when the operation frequency of a compressor is fixed.
Above data does not take Freeze Prevention Protection during cooling operation into account.
For this reason, the value may vary from the actual cooling characteristics.
NOTE
33