beautypg.com

Error display – Panasonic EYFLA6PR User Manual

Page 15

background image

- 15 -

Checking tool circuits

1. Press the torque level button.

• Control panel display

Display: The torque set display lights up.

Battery indication lamp: The middle and

lower bars of the battery flash on and off.

Display

Tool circuit

H6

EYFLA4

H7

EYFLA5

H8

EYFLA6

H9

EYFMA1

NOTE:

• If you engage the switch while a setting

is being displayed, the control panel will

revert to the torque clutch setting dis-

play.

CAUTION:

• The torque set display is not intended

to be used to identify the type of drive

component parts (hammer, etc.) used

in a particular tool.

Error Display

In the event of a tool or battery pack malfunction, the control panel will display an error message.

Please check the tool or battery pack as described in the following chart before having them

serviced.

Display

Likely cause

Corrective action

Setting error

Re-initialize the tool using the

remote control. (See page 14.)

The battery pack is too hot.

Stop work and allow the battery

pack to cool before resuming use

of the tool.

The tool is too hot to operate.

Stop work and allow the tool to

cool before resuming use.

The contacts that connect the

battery pack and tool are dirty.

Remove any dirt.

The battery pack has not been

properly inserted into the tool.

Insert the battery pack firmly into

the tool.

The pins on either the tool or

battery pack have worn down.

Replace the battery pack.

Motor failure, etc.

Stop using the tool immediately.

Tool circuit malfunction, failure,

etc.

The tool is unable to communi-

cate with the Assembly Quali-

fier while the radio signal range

limitation function is on.

• Verify that the tool has been

properly registered to the Assem-

bly Qualifier.

• Verify that the Assembly Qualifi-

er’s group setting has been con-

figured correctly.

• Improve the reception state, for

example by moving the Assem-

bly Qualifier closer to the tool.