Panasonic EYFLA6PR User Manual
Page 12
- 1 -
• You can select from 30 torque clutch
settings (1 to 30).
• Use figures from the Tightening Torque
Chart to guide your selection of torque
clutch setting. (See the following tighten-
ing torque chart)
. Press the OK button to accept the select-
ed torque clutch setting.
• The control panel will stop flashing and
light up.
CAUTION:
• You must press the OK button in order
for the selected setting to take effect.
• Be sure to verify the new value after
changing the setting. (See page 14.)
Setting the snug point detection level
()
(3)
(1)
1. Press the torque setting mode button.
• The snug point detection level setting
value will be displayed.
Display
Battery indication lamp
. Press the and buttons to set the best
snug point detection level for the work
you’re performing.
Display
Snug point detection level
L1
Low
(Use for work characterized by
low loads before the snug point
is reached.)
L
High
(Use for work characterized by
high loads before the snug point
is reached.)
3. Press the OK button to accept the number
of torque stages and the snug point detec-
tion level.
• The tool’s panel will flash and then light
up continuously.
CAUTION:
• Set the snug point detection level from
“L1.” Setting the snug point detection level
from “L” may result in cracking or defor-
mation of the target material.
• If the tool stops before the snug point at
snug point detection level “L1,” set the
snug point detection level to “L.”
• Changing the snug point detection level
from “L1” to “L” may increase the torque.
Set the number of torque stages again
after making this change.
• The setting will not be changed until
you press the OK button.
• After changing the setting, be sure to check
the new setting value. (See page 14.)
IMPORTANT INFORMATION:
• You can set the snug point detection
level and retightening prevention time at
the same time by changing the retight-
ening prevention time (see page 13)
before pressing the OK button and then
pressing the OK button.
• Pressing the torque setting mode but-
ton toggles the display between the
snug point detection level setting value
and the number of torque stages set-
ting value.
• The tool ships with the snug point
detection level set to “L1.”
• When the number of torque stages has
been set as shown below, the snug
point detection level cannot be switched
from “L1” to “L.”
Model
Number of torque stages
setting
EZFLA4
1 to 8
EZFLA5
1 to 3