Installation – Alliance Laundry Systems SF18VNV User Manual
Page 28
Installation
26
F232060
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
.
Note:
The X voltage is not compatible with
CE and/or electric heat models.
IMPORTANT: For machines with X
voltage: If input power is single-phase,
connect L1 to L1 of terminal block and L2
to L2 of terminal block. Leave L3
unconnected on the input terminal block. If
input power is three-phase, connect L1, L2
and L3 to L1, L2 and L3 of the terminal
block.
Cabinet Freestanding
Electrical Specifications
Voltage Designation
Standard
Electric Heat
M
ode
l
Code
Vo
lt
a
g
e
Cy
c
le
P
h
ase
Wir
e
Fu
ll Loa
d
Amps
Bre
aker
AW
G
mm
2
Fu
ll Loa
d
Amps
Bre
aker
AW
G
mm
2
18
X
200-240
50-60
1 or
3
2 or
3
6/4
15
14
2x2.5
3x2.5
--
--
--
--
P*
380-415
50-60
3
3
3
15
--
3x2.5
12
15
--
3x2.5
Q
200-240
50-60
3
3
5
15
14
--
18
20
12
--
T*
200-240
50-60
1
2
8
15
14
--
31
35
8
--
25
X
200-240
50-60
1 or
3
2 or
3
11/6
15
14
2x2.5
3x2.5
--
--
--
--
P*
380-415
50-60
3
3
3
15
--
3x2.5
12
15
--
3x2.5
Q
200-240
50-60
3
3
7
15
14
--
18
20
12
--
T
200-240
50-60
1
2
12
15
14
--
31
35
8
--
Note: Wire sizes shown are for copper, THHN, 90° conductor per NEC article 310.