Electrical Requirements

• A 120-volt, 60-Hz., AC-only, 15 or 20-amp, fused electrical

supply is required. Time-delay fuse or circuit breaker is

recommended. It is recommended that a separate circuit

serving only this appliance be provided.

• This washer-dryer is equipped with a 6’ power supply

cord having a 3-prong ground plug.

• To minimize possible shock hazard, the cord must be

plugged into a properly grounded (3) prong electrical

outlet capable of 120 Volt, 60 Hz and grounded in ac-

cordance with local codes and ordinances. If a mating

outlet is not available, it is the personal responsibility

and obligation of the customer to have the properly

grounded outlet installed by a qualified electrician. The

outlet shouldn’t be controlled by a wall switch or pull

cord which can be turned off accidentally.

• If codes permit and a separate ground wire is used, it is

recommended that a qualified electrician determine that

the ground path is adequate.

• Do not ground to a plastic plumbing lines, gas lines or

water pipes.

• Check with a qualified electrician if you are not sure the

washer is properly grounded.

• DO NOT use an extension cord.

• DO NOT have a fuse in the neutral or ground circuit.

• DO NOT install or store this appliance where it will be

exposed to weather or in an area where gasoline or other

flammables are stored.

GROUNDING INSTRUCTIONS

Electrical Shock Hazard

(Death, Fire, or Electric Shock)

This appliance must be grounded.

This appliance should be connected to an

Individual Branch Circuit with N.14 AWG Wire

and Protected by 15A fuse

In the event of a malfunction, or breakdown,

grounding will reduce the risk of electric shock

by providing a path of least resistance for

electric current. This appliance is equipped

with a cord having an equipment grounding

conductor and grounding plug. The plug must

be plugged into an appropriate outlet that is

properly installed and grounded in accordance

with all local codes and ordinances. DO NOT

modify the plug provided with the appliance.

If it will not fit the outlet, have the proper out-

let installed by a qualified electrician.

WARNING: Improper connection of the

equipment-grounding conductor can result

in a risk of electric shock. Check with a

qualified electrician or serviceman if you

are in doubt as to whether the appliance is

properly grounded.

ELECTRICAL SHOCK HAZARD

Plug washer-dryer into a
grounded 3 prong outlet.

Do not remove ground prong.

Do not use adapter.

Do not use an extension cord.

Failure to follow these
instructions can result in death,
fire, or electrical shock.

WARNING

!

Installation Requirements