Extended standard menu, Als 230, 2 extended standard menu – Avery ALS 230 User Manual
Page 37

Operators Manual
ALS 230
Release 11/05
Page 35
Menu structure
5.2 Extended standard menu
The extended standard menu offers additional parameters you may use in your application.
On quitting this menu the current parameter settings are stored in memory. Further changes
are also written into memory. As long as this menu is active, no labelling is possible. By
pressing the key FEED, however, single dispense of labels is possible.
To get into the extended standard menu a password CODE has to be entered. The display
shows the first menu point. A survey of all parameters is shown below.
Display Function
Data
value
LPIT
Label pitch
AUTO/5...999 mm
CONT
Label sensor contrast value
AUTO/1...200
SENS
Sensor status
LAB or GAP
STOD
Stop position of label at the dispensing edge
0.0 .... 200.0 (mm)
PRDL
Product length (inhibit of further product- sensor
signals)
AUTO, 5 ... 999 mm
POS
Position of label on product
Up to 999.9 mm
STAD
Delay time for start of applicator cycle
1 ... 9999 ms
VELO
Labelling speed
0.2 ... 30 m/min
STST
Check adjusted EGRA value
see text
SLEW
Slew speed
FAST or SLOW
EGRA
Electronic gear ratio adjustment
100 to 500
APT1
Dwell time for applicator
1 ... 7500 ms
APT2
Blow on time for applicator
1 ... 7500 ms
APT3
Restart delay
0 ... 5000 ms
APT4
Time constant compensation
0 ... 500 ms
ASTP
End of air stream signal
-20 ... 50 mm