A. No power. Display will not light.

1. Verify that power is available at the outlet or junction box.

2. Verify that the circuit breaker switch on the back of the unit is turned on.

3. Verify that the power cord is not open. Check continuity with a VOM meter.

4. If none of the above steps help, call a qualified service technician or refer to the Service Manual for

this particular oven.

B. Display is lit and unit calls for heat, but unit is not heating;

Error Code E-30

Check to verify that the high limit switch located at the rear of the unit top has not been

tripped. If it has been tripped, reset by pressing in the hit limit reset button at the rear

of the oven.

After resetting, the cause of the high limit trip must be corrected. If the high limit switch

will not reset, the high limit switch is defective and must be replaced.

This is a safety

device and must not be jumped out or removed from the circuit.

C. To test air sensor:

Test air sensor by placing sensor in ice water bath and using an ohmmeter set on the ohm scale.

The reading should be 100 ohms resistance. If it is more than 2 ohms higher or lower, sensor needs to

be replaced.

D. To test probe sensor:

Test food probe by placing in ice water bath and using an ohmmeter set on the ohm scale. The reading

should be 100 ohms resistance.

TROUBLE SHOOTING INTERNAL ELECTRICAL COMPONENTS

This section is provided for the assistance of qualified technicians only and is not intended for use by

untrained or unauthorized service personnel. If your Alto-Shaam

®

unit is not operating properly, check the

following before calling your Authorized Alto-Shaam

®

Service Agent:

*

Check the power flow to the unit. Plug in outlet? Circuit breaker switch at back of unit turned on?

Do not attempt to repair or service the Cook and Hold unit beyond this point. Contact Alto-Shaam

®

for the nearest authorized service agent. Repairs made by any other service agents without prior

authorization by Alto-Shaam

®

will void the warranty on the unit.