O P E R A T I N G I N S T R U C T I O N S

To stop an operation at any time Press and hold

the s

tart

Key until the control beeps for two seconds,

indicating the operation has been cancelled. The oven

will remain in a power-on state.
To turn oven control panel off Press and hold the

o

N

/o

ff

Key until the oven beeps. The O

N

/O

ff

indicator

light will go out.
Door open indicator — Display will flash “door” and

a triple beep will alert the user. Press O

N

/O

ff

key to

acknowledge error and disable triple beep.
Arrow Keys:
Cook, Hold and Probe Temperature
set points can be

adjusted by 1° when pressing the a

rrow

Keys. To adjust

in steps of 10°, press and hold the t

emperature

Key and

a

rrow

Key at the same time.

The Time setting is adjusted in increments of 1 minute by

pressing the a

rrow

Keys. To make adjustment in steps of

10 minutes, press and hold the t

ime

Key and a

rrow

Key at

the same time.
Green and Amber Indicators:
Each program key includes a green

light which indicates a requirement

for additional programming by the

operator or the current operational

state of the oven.
The c

ook

, t

iMe

, p

rob

e

, and h

old

keys include an amber

indicator light to identify the information being displayed.
Power Fail Detect:
If the power were to fail for any reason while heating, the

control will retain, in memory, the programmed operating

conditions. When power is restored, the control will

resume operating from the point where it was interrupted

and the O

N

/O

ff

indicator light will flash, indicating that

such an event did occur. The operator can acknowledge

the power failure by pressing the O

N

/O

ff

key. Pressing

the key will display the amount of time that the power

has been off. The control will stop counting the amount

of time the power has been off when it has been off for

more than 24 hours.
NOTE: If such an event has occurred, it is strongly

recommended that you ensure the food is safe for

consumption according to local health regulations.
Display High/Low Probe Temperatures:
To observe the recorded maximum or minimum probe

temperature when cooking by probe, press the following

keys while the probe remains in the product:
Highest Temperature: Press p

robe

Key and u

p

a

rrow

Key at same time.
Lowest Temperature: Press p

robe

Key and d

own

a

rrow

Key at same time.

Probe Usage:
When the oven probe remains inserted in the probe

bracket, the LED temperature display will indicate the

ambient air temperature inside the oven. To use the

probe for cooking remove it from the bracket and wipe

the full length of the metal probe with a disposable

alcohol pad to clean and sanitize before using.
Only the tip of the probe senses the internal product

temperature; therefore, it is important the tip be placed

correctly in the product for internal temperature accuracy.

Push the probe tip halfway into the product, positioning

the tip at the center of the food mass. When inserting

the probe into solid foods such as meat roast or poultry

breasts, push the probe in from a straight downward

position or in from the side to the center position. If

placing into a semi-liquid or liquid product, the probe

cable must be secured to keep the probe positioned

properly. Do not let the probe tip touch the edges,

bottom or side of a container. Tape the probe cable to the

lip or edge of the container.

Probe Calibration:
1.
To verify product probe calibration, place the

probe in a warm glass of water along with a

quality independent digital thermometer and

press the probe key for two (2) seconds to

display the probes actual temperature. Compare

readings.

2. If calibration is required, press the probe key

for eight (8) seconds until the unit beeps twice

and the probe offset is displayed. Adjust the

probe offset to match the difference between the

independent probe temperature and the control

probe temperature by pressing the up or down

arrows to increase or decrease the offset.

3. Repeat steps 1 and 2 to verify the probe

calibration as necessary.

OPERATING FEATURES & FUNCTIONS

NOTE:

When cooking by probe, insert the probe

into the raw product after the oven has been

preheated.

WAIT ONE FULL MINUTE to allow the probe

temperature to decrease to the internal temperature

of the product. Press the start button to begin

the cooking process after this probe temperature

adjustment period. A false probe reading of the

internal product temperature will cause the oven to

default to a holding temperature.

I

o

Amber