MULTI AIR CONDITIONER SYSTEM
DEFINITION
Multi air conditioner systems save space by letting you connect multiple indoor units to a single outdoor unit.
OPERATION CONDITION
OPERATION CONDITION
Multi Split Outdoor Unit
(CU-2E15LBE, CU-2E18LBE, CU-3E18LBE, CU-4E23LBE, CU-4E27CBPG)
Temperature (°C)
Indoor
Outdoor
Outdoor
CU-2E15LBE, CU-2E18LBE,
CU-4E27CBPG
CU-3E18LBE, CU-4E23LBE
*DBT *WBT
*DBT
*WBT
*DBT
*WBT
COOLING
Max.
32
23
43
26
46
26
Min.
16
11
16
11
-10
-
HEATING
Max.
30
-
24
18
24
18
Min.
16
-
-10
-11
-15
-16
* DBT: Dry bulb temperature
* WBT: Wet bulb temperature
Room A
Room A
Living room
Living room
Outdoor Unit
Outdoor Unit
INDOOR UNIT
INDOOR UNIT
• It is possible to operate the indoor units individually or simultaneously. The operation mode priority is given to the
fi rst unit that turned on.
• During operation, heating and cooling mode could not be activated at the same time for different indoor unit.
The power indicator blinks to indicate the indoor unit is standing by for different operation mode.