CAUTION

CAUTION

INDOOR UNIT AND OUTDOOR UNIT

Do not wash the indoor unit with water,

benzene, thinner or scouring powder.
Do not use for other purpose such as

preservation of food.
Do not use any combustible equipment in front

of the airfl ow outlet to avoid propagation fi re.
Do not expose yourself directly to cold air for a

long period.
Do not sit or step on the unit, you

may fall down accidentally.

Do not touch the sharp aluminium fi n,

sharp parts may cause injury.

Do not switch ON the indoor unit when waxing

the fl oor. After waxing, aerate the room properly

before operating the unit.
Do not install the unit in oily and smoky areas.
Ensure drainage pipe is connected properly.

Otherwise, leakage may occur.
Aerate the room regularly.
After long period of use, make sure the

installation rack is not deteriorate to prevent the

unit from falling down.

REMOTE CONTROL

Do not use rechargeable (Ni-Cd) batteries.

It may damage the remote control.

Remove the batteries if the unit is not going to

be used for a long period of time.
New batteries of the same type must be

inserted following the polarity stated to prevent

malfunction of the remote control.

WARNING

WARNING

POWER SUPPLY

Do not use modifi ed cord,

joint cord, extension cord or

unspecifi ed cord to prevent

overheating and fi re.
Do not share the same power outlet with other

equipment to prevent overheating and fi re.
Do not operate with wet hands to prevent electric

shock.
If the supply cord is damage, it must be replaced

by the manufacturer, its service agent or similarly

qualifi ed persons in order to avoid a hazard.
It is strongly recommended to be installed

with Earth Leakage Circuit Breaker (ELCB)

or Residual Current Device (RCD) to prevent

electric shock or fi re.
This equipment must be earthed to prevent

electrical shock or fi re.

In case of emergency or abnormal conditions

(burnt smell, etc), turn off the power supply, and

please consult authorized dealer.
Prevent electric shock by switching off the power

supply when:

- Before cleaning or servicing.

- Extended non-use.

- Abnormally strong lightning activity.

Air Inlet

Air Inlet

Air Outlet

Air Outlet

Power

Supply

Outdoor

Unit

OPERATION CONDITION

OPERATION CONDITION

Use this air conditioner under the following temperature range
CU-E10HBEA

Temperature (°C)

Indoor

Outdoor

*DBT *WBT *DBT *WBT

COOLING

Maximum

32

23

43

26

Minimum

16

11

-10

-

HEATING

Maximum

30

-

24

18

Minimum

16

-

-10

-

NOTICE:
• This unit is still able to operate as a cooler with outdoor

temperature as low as -10°C in a non-living room, such

as a computer room, with a room temperature of 16°C or

above, and room humidity up to 80%. When the outdoor

temperature drops to -10°C, compressor will be cut off and

resume operation again once the temperature rises to more

than -10°C.

• When the outdoor temperature is out of the above

temperature range, the heating capacity will drop

signifi cantly and outdoor unit might stop for protection

control.

* DBT: Dry bulb temperature

* WBT: Wet bulb temperature