Maintenance

21

9001001

3. Remove back panel and check overflow hose and

drain hose for leaks.

4. Clean inlet hose filter screen:

a. Turn water off and allow valve to cool, if

necessary.

b. Unscrew inlet hose and remove filter screen.

c. Clean with soapy water, rinse and reinstall.

Replace if worn or damaged.

5. Check the supply dispenser hoses for leaks.

6. Use compressed air to clean lint from motor.

7. Clean interior of machine, both basket and shell,

by wiping with a water-soaked sponge or cloth.

8. Use compressed air to ensure that all electrical

components are free of moisture and dust.

9. Verify that insulation is intact on all external

wiring and that all connections are secure. If bare
wire is evident, call a service technician.

10. If necessary, tighten the bearing housing’s

mounting bolts.

11. If necessary, tighten the shock absorber’s

mounting bolts.

Yearly

1. Replace the automatic lubricator (only for 75-

100-135-165 machine). Failure to do so could
void the warranty.

2. Check if the machine is working properly. If you

see or hear any abnormal function on the
machine call a service technician.