After first two hours of operation.

CHECK DUAL HANDLE
INTERLOCK

Without the engine running, press down
(engage) both clutch levers. Release
attachment clutch lever. Attachment clutch
should remain engaged until traction clutch
lever is released, then both clutches must
disengage.

CHECK FASTENERS

Make sure all hardware is tightened properly.

CHECK CLUTCHES

Auger / impeller must stop within 3 seconds
when attachment clutch/impeller brake lever is
released.
Wheels must stop quickly when traction drive
clutch lever is released.

If clutches do not engage or disengage
properly, adjust or repair before operation (see
Service and Adjustments).

CLEAN ENGINE

Refer to Engine Manual for detailed
instructions.

CHECK ENGINE OIL

The engine crankcase oil should be checked
every 5 hours of operation. Oil level MUST be
maintained in safe operating range on dipstick
at all times or engine damage will result (See
Engine Manual).
Park unit on a level surface. Refer to Engine
Manual for detailed instructions.

CHANGE ENGINE OIL

Change oil after first 2 hours of operation,
thereafter change oil every 25 hours (more
often if required). Refer to Engine Manual for
detailed instructions.

Run engine just prior to changing oil. Warm oil
will flow more freely and carry away more
contamination. Remove the oil drain plug from
the rear of the unit and tip the unit back to help
drain all the oil.

CHECK TIRE PRESSURE

Keep tires at pressure listed on the tire
sidewall.

CHECK AUGER GEARCASE

IMPORTANT: Proper oil level must be
maintained.
Gear cases are filled to the correct level at the
factory. Unless there is evidence of leakage,
no additional lubricant should be required.
Check oil level each season or every 25 hours
of operation.

To ensure adequate lubricant level:

1. Remove filler plug (Figure 10). Lubricant

must be at least up to bottom of lubricant
filler hole with unit resting on a
level-surface.

2. Add lubricant if required. Allow oil to drain

to level of plug and replace plug.

IMPORTANT: Use only Ariens special gear
lubricant L-2 (Part Number 00008000).

MAINTENANCE

SCHEDULE

Service
Performed

Each

Use

Every
5 hrs.

Every

25

hrs.

Yearly

Check Dual
Handle
Interlock

Check
Fasteners

Check
Clutches

Clean Engine

Check Engine
Oil

Change
Engine Oil

*

Check Tire
Pressure

Check Auger
Gearcase

General
Lubrication

Figure 10

1. Auger Gearcase
2. Filler Plug

OS6775