beautypg.com

Indicators – Sony VPL-DX145 User Manual

Page 39

background image

17

GB

Indicators

Indicators

The indicators allow checking the status and notify you of abnormal operation of the projector.
If the projector exhibits abnormal status, address the problem in accordance with the table
below.

ON/STANDBY indicator

LAMP/COVER indicator

Status

Meaning/Remedies

Lights in red

The projector is in Standby mode.

Flashes in green

• The projector is ready to operate after having been turned on.
• The lamp cools after the projector is turned off.

Lights in green

The projector’s power is on.

Lights in orange

The projector is in With No Input (Lamp Cutoff).

Flashes in red

The projector is in abnormal status. Symptoms are indicated by
number of flashes. Address the problem in accordance with the
following. If a symptom persists, despite having taken measures
below, consult with qualified Sony personnel.

Flashes twice

The internal temperature is unusually high. Check the items below.
• Check if nothing is blocking the ventilation holes.
• Check if the air filter is not clogged. (page 20)
• Check if the Installation Attitude in the Installation menu is set

correctly.

Flashes six times

Unplug the AC power cord from a wall outlet. After checking that the
ON/STANDBY indicator goes out, plug the power cord to a wall
outlet again then turn on the projector.

Other number of
flashes

Consult with qualified Sony personnel.

Status

Meaning/Remedies

Flashes in red

Symptoms are indicated by number of flashes. Address the problem in
accordance with the following.

Flashes twice

The lamp cover is not attached securely. (page 18)

Flashes three times The temperature of lamp is unusually high. Turn off the power and

wait for lamp to cool then turn on the power again. If the symptom is
shown again, the lamp may be burnt out. In this case, replace the lamp
with a new one (page 18).