6.8 TOR – Maximum Reading Time
Timeout for the reader. TOR is used in operation mode 2 as maximum gating time for a
reading process . The length of the maximum gating time results from the equation gat-
ing_time = TOR * TB.
The time constant TB (Time Base) has always the default value 100ms.
Input format:
TOR
Parameter:
Function
0
limits the reading process duration to exactly one reading cycle
1
limits the reading process duration to maximum 1 times TB
2
limits the reading process duration to maximum 2 times TB
...
255
limits the reading process duration to maximum 256 times TB
Output (example):
2
6.9 VS- Show Parameter
The command VS lists all current parameter settings.
Input format:
VS
Output (example):
EC
BD
MD
6.10 VSAVE – Save Parameter
All operating parameters temporarily stored are saved permanently using VSAVE.
Input format:
VSAVE
Output:
ok