Diode checks – Actron CP9087 User Manual
Page 86
Section 4
4-4
Diode Checks
Tests diodes and rectifiers for proper operation.
1) Set RANGE switch to HIGH.
2) Set FUNCTION switch to OHMS.
3) Connect TEST leads as shown in Figure 1.
( YELLOW to anode — BLACK to cathode)
4) The bottom TEST light should be ON. If a
different TEST light is on or all lights are off, the
diode is defective.
5) Reverse test lead connections as shown in
Figure 2.
( YELLOW to cathode — BLACK to anode)
6) The top TEST light should be ON. If a different
TEST light is on or all lights are off, the diode is
defective.
Note: Always make sure all connections are good. If
necessary, scrape away corrosion, paint, etc. at the
contact points.