beautypg.com

Oxygen – Actron CP9087 User Manual

Page 33

background image

OXYGEN

2-25

11) Observe RICH/LEAN lights while operating

sensor.

• After sensor tip is hot. move the flame until the
sensor tip is completely surrounded by the flame.
This keeps oxygen away from the tip. See Fig. 2.

– Good Sensor: RICH light turns ON within 3
seconds indicating a “rich” (low oxygen) condition.

– Bad Sensor: RICH light takes longer than 3
seconds to turn on, or does not turn on at all.

• Move flame so oxygen can reach sensor tip.
(Keep sensor tip hot with flame.) See Fig. 1.

– Good Sensor: LEAN light turns ON within 3
seconds indicating a “lean” (high oxygen) condition.

– Bad Sensor: LEAN light takes longer than 3
seconds to turn on, or does not turn on at all.

12) Repeat step 11 a few times to verify results.

13) Testing is complete.

Extinguish flame, set RANGE switch to POWER
OFF, let sensor cool and remove test leads.

IMPORTANT: Special anti-seize compound must be
applied to sensor housing threads before reinstallation.
Refer to vehicle service manual for proper type.

RICH

LEAN

RICH

LEAN

Fig. 1

Fig. 2