USER MANUAL

10

FLOORTEC R 680 P

1463514000(1)2008-05 A

Dust vacuuming and fi ltering

Values

Paper dust fi lter 15-20 μm

3.6 m

2

Main broom compartment vacuum

10.9 mm/H

2

O

Electrical system

Values

Batteries

2 x 12 V – 70 Ah

Vacuum system motor

310 W, 3,000 rpm

Main broom motor

500 W, 550 rpm

Filter shaker motor

90 W, 5,700 rpm

Closed pocket fi lter shaker motor (optional)

110 W, 3,000 rpm

Drive system

Values

Drive system pump

SAUER HIDRO-GEAR BDP 10A

Drive system pump displacement

10.2 cm

3

Filling pump displacement

1.9 cm

3

Maximum working pressure

70 Bar

Maximum peak pressure

145 Bar

Hydraulic system oil tank capacity

0.8 litres

Hydraulic circuit total capacity

1.2 litres

Oil type

SAE 10 W 40

Hopper hydraulic lifting system

Values

Pump

Parker 108 AE S32 – 24 V

Maximum pressure

110 Bar

Oil tank capacity

0.75 litres

Hydraulic circuit total capacity

1.4 litres

Hydraulic system oil (at ambient temperature above 10°C)

AGIP Arnica 46 (*)

CAUTION!
If the machine is to be used at ambient temperatures below +10°C, the oil should be changed with equivalent oil
having a viscosity of 32 cSt. For temperatures below 0°C, use an oil with lower viscosity.

See the oil technical data and reference data tables below.

(*)

TECHNICAL DATA

REFERENCE DATA

AGIP ARNICA

46

32

ISO-L-HV

Viscosity at 40°C

mm

2

/s

45

32

ISO 11158

Viscosity at 100°C

mm

2

/s

7.97

6.40

AFNOR NF E 48603 HV

Viscosity index

/

150

157

AISE 127

Flash point COC

°C

215

202

ATOS Tab. P 002-0/I

Pour point

°C

-36

-36

BS 4231 HSE

Density at 15°C

kg/l

0.87

0.865

CETOP RP 91 H HV

COMMERCIAL HYDRAULICS

Danieli Standard 0.000.001 (AGIP ARNICA22,46,68)

EATON VICKERS I-286-S3

EATON VICKERS M-2950

DIN 51524 t.3 HVLP

LAMB LANDIS-CINCINNATI P68, P69, P70

LINDE

PARKER HANNIFIN (DENISON) HF-0

REXROTH RE 90220-1/11.02

SAUER-DANFOSS 520L0463