Anterus tags configuration options – AMX Control System Accessories Anterus User Manual
Page 26

Anterus Configuration Manager
22
Anterus RFID Solution
Anterus Tags Configuration Options
The lower section of the Global Register page contains Tag configuration options. There is a separate
entry for each Tag in the Anterus system (FIG. 20):
FIG. 23
Tag Configuration Options (Global Register page)
Tag Configuration Options (Global Register page)
• Tag ID:
Indicates the Tag ID assigned to each Tag (display-only).
• Name:
Use this field to assign a friendly name to each Tag (optional).
Click the Accept button to save your changes.
• Detail:
Click the Detail icon to access a popup window containing detailed info (read-
only) on the selected Tag (see the Viewing Tag Details section on page 23).
• Info:
Use this field to assign a descriptive string to each Tag (optional).
Click the Accept button to save your changes.
• Acquired Threshold:
The Tag’s Acquired Threshold value works in conjunction with the Reader's
Acquired Threshold setting, and can be used to further filter active RFID Tag
messages (via the Reader's Filter Tag Levels option).
Note: The Tag’s Acquired Threshold value does not override filtering already
configured on the Reader.
Click the Accept button to save your changes.
• Status (Acquired/Offline): Indicates the current status of the selected Tag (display-only).
• Acquired indicates that the Tag has been detected by the Reader and is
currently being tracked by the RFISD Reader.
• Offline indicates that the Tag has moved out of range, and is currently below
the Acquired Threshold
• Delete:
Click to remove any Tag from the Anterus system (see the Removing a Tag
from the System section on page 21).
• Add Tag:
Click to add a new Tag to the system (see the Adding a Tag to the
System section on page 21).
Next Tag
Next Page
Previous Tag
Previous Page
Click to add a new Tag
Click to access a Tag Details
popup window for each Tag
Click to
delete a
Tag