Troubleshooting Guide

Trouble

Probable Cause

Solution

Couplers are not securely attached to
the tool or pump

Check the Coupler connections and make
certain that they are connected.

Coupler is defective

Replace any defective Coupler.

Defective remote control switch

Replace the switch and/or control pendent

Piston will not advance or
retract

Dirt in the direction-control valve of
the pump unit

Disassemble the pump and clean the
direction-control valve.

Hose connections reversed

Make certain the advance on the pump is
connected to the advance on the tool and
retract on the pump is connected to the
retract on the tool.

Retract hose not connected

Connect the retract hose securely

Piston will not retract

Retract pin and/or Spring broken

Replace the broken pin and/or spring

Piston Seal and/or End Plug Seal
leaking

Replace any defective O-rings

Retaining Screws sheared

Replace any broken screws.

Cylinder will not build up
pressure

Coupler is defective

Replace any defective Coupler

Grease or dirt build up in the teeth of
the Ratchet and Segment Pawl

Disassemble the Ratchet and clean the
grease or dirt out of the teeth

Ratchet will not turn

Worn or broken teeth on Ratchet an/or
Segment Pawl

Replace any worn or damaged parts

Tool tightens immediately
when turned on

Hose connections are reversed

Depress the advance button to release the
tool; shut the pump off in the advance
position and reverse the hose connection

Defective relief valve

Inspect, adjust or replace the relief valve

Air supply too low or air hose too small

Make certain the air supply and hose size
comply with the pump manual
recommendations.

Electric power source is too low

Make certain the amperage, voltage and
any extension cord size comply with the
pump manual requirements

Defective Gauge

Replace the Gauge

Low oil level

Check and fill the pump reservoir

Pump will not build up
pressure

Clogged filter

Inspect, clean and/or replace the pump
filter

Pressure reading erratic

Defective Gauge

Replace the Gauge

Nut Returns with retract
stroke

Ball Plungers are not engaging the
Drive Sleeves

Thread the Ball Plungers to the correct
depth in the Housing.