Karcher HD 13-35-4 User Manual
Page 26
– 12
Type
HD 13/35-4
1.367-152.0
HD 9/50-4
1.367-153.0
Power connection
Voltage
V
440
Current type
Hz
3~60
Connection output
kW
15
Mains fuse (slow-blow)
A
30
Protective class
IPX5
Maximum allowed net impedance
Ohm
(0.164+j0.103)
Water connection
Max. feed pressure
MPa (bar)
1 (10)
Inflow pressure (min.) with max. water volume MPa (bar)
0,05 (0,5)
Max. feed temperature
°C
60
Min. feed volume
l/h (l/min)
1500 (25)
1100 (18,3)
Inlet hose length (min.)
m
7,5
Inlet hose diameter (min.)
Inch
1
Performance data
Working pressure
MPa (bar)
5...35
(50...350)
15...50
(150...500)
Max. excess operating pressure (safety valve) MPa (bar)
45 (450)
64 (640)
Water flow rate
l/h (l/min)
500...1300
(8,3...21,7)
500...900
(8,3...15)
Nozzle size
--
15046
15028
Recoil force of trigger gun
N
93
79
Fuel
Oil quantity - pump
l
1,3
Oil type - pipe
SAE 90 Hypoid
Dimensions and weights
Length x width x height
mm
1025 x 780 x 1100
Weight without accessories
kg
190
Air pressure of wheels
MPa (bar)
0,20 (2,0)
Values determined as per EN 60355-2-79
Hand-arm vibration value
Hand spraygun
m/s
2
0,87
Spray lance
m/s
2
1,8
Uncertainty K
m/s
2
1
Sound pressure level L
pA
dB(A)
78
Uncertainty K
pA
dB(A)
2
Sound power level L
WA
+ Uncertainty K
WA
dB(A)
95
94
26
EN