beautypg.com

Karcher HD 13-35-4 User Manual

Page 18

background image

– 4

Warning

Risk of injury on account of unsuitable ac-
cessories. Only use accessories approved
for the working pressure of the appliance
(see "Specifications").
Only install accessories when the appli-
ance is switched off.
The maximum torque for the screw connec-
tions of the high pressure hose is 20 Nm.

Connect high pressure hose and spray
pipe to the hand spray gun.

Mount the power nozzle on the spray
pipe. Tighten covering nut firmly.

Connect the high pressure hose to the
high pressure connection point of the
machine.

For connection values refer to technical
specifications

The electrical connections must be
done by an electrician according to IEC
60364-1.

Warning

The highest allowed net impedance at the
electrical connection point (refer to techni-
cal data) is not to be exceeded.
In case of confusion regarding the power
impedance present on your connection,
please contact your utilities provider.

ƽ

Danger

Check whether the voltage indicated on
the type plate corresponds to the volt-
age of the socket.

Unsuitable extension cables can be
hazardous. Only use extension cables
outdoors which have been approved for
this purpose and labelled with a suffi-
cient cable cross section:
1 - 10 m: 4 mm

2

10 - 30 m: 6 mm

2

With this appliance model, the matching
mains plug must be installed onto the
mains connecting line by an electrician.

Warning

Observe regulations of water supplier.
According to the applicable regula-
tions, the appliance must never be
used on the drinking water supply
without a system separator. Use a
suitable system separator manufactured by
KÄRCHER; or, as an alternative, a system
separator as per EN 12729 Type BA. Water
flowing through a system separator is con-
sidered non-drinkable.
Caution
Always connect the system separator to
the water supply, never directly to the appli-
ance!
Quality requirements for water:

For connection values, see type plate/tech-
nical data.

Use a fibre-reinforced hose (not includ-
ed in standard delivery).
Diameter should be minimum 1".

Connect the hose to the water connec-
tion of the appliance.

Connect the hose to the water tap.

Attaching the Accessories

Power supply

60 Hz model

Water connection

Parameter

Value

pH value

6,5...9,5

electrical conductivity

max. 2000
μS/cm

Hydrocarbons

< 0.01 mg/l

Chloride

< 250 mg/l

Calcium

< 200 mg/l

Total hardness

< 28 °dH

Iron

< 0.2 mg/l

Manganese

< 0.05 mg/l

Copper

< 0.02 mg/l

Sulphate

< 240 mg/l

Active chloride

< 0.1 mg/l

free of bad odours

18

EN

This manual is related to the following products: