beautypg.com

Karcher SC 1-020 User Manual

Page 14

background image

– 7

If couplings of the power cord or extension
cable are replaced the splash protection and
the mechanical tightness must be ensured.

The operator must use the appliance cor-
rectly. When working with the appliance, he
must consider the local conditions and pay
due care and attention to other persons, in
particular children, who are nearby.

This device is not intended for use by per-
sons (including children) with reduced phys-
ical, sensory or mental abilities or lacking
experience and/or knowledge, unless they
are supervised by a person responsible for
their safety or are instructed by these per-
sons on the use of the device. Children
should be supervised, to ensure that they do
not play with the device.

Never leave the appliance unattended when
it is in operation.

Be very careful while cleaning tiled walls with
sockets.

Caution

Make sure that the power cable or extension
cables are not damaged by running over,
pinching, dragging or similar. Protect the
power cable from heat, oil, and sharp edges.

Never fill solvents, solvent-containing liquids
or undiluted acids (e.g. detergents, benzene,
paint thinner, and acetone) into the water
reservoir as these substances affect the ma-
terials used on the appliance.

The appliance must provide of a stable
ground.

Use and store the unit only in accordance
with the specifications in the description and/
or figure.

The steam switch must not be locked during
the operation.

Protect the appliance from rain. Do not store
outside.

Caution
Safety devices protect the user and must not be
modified or bypassed.

The pressure controller keeps the boiler pres-
sure during the operation as constant as possi-
ble. The heating is turned off if the maximum
operating pressure of 4 bar is reached in the boil-
er and is reactivated in case of a pressure drop
in the boiler due to steam tapping.

The safety thermostat turns off the appliance if
the boiler thermostat and the pressure controller
fails and the appliance overheats in case of a
malfunction. Please contact your local KÄRCH-
ER customer service to arrange for the reset of
the safety thermostat.

The safety lock seals the boiler against the
steam pressure that builds up in the boiler. If the
pressure controller is defect and the steam pres-
sure in the boiler rises, a pressure control valve
in the safety lock opens, and steam is emitted
through the lock to the outside.
Please contact your local KÄRCHER customer
service before you put the appliance into opera-
tion again.

Safety Devices

Pressure controller

Safety thermostat

Safety lock

14

EN

This manual is related to the following products: