beautypg.com

Storage transport maintenance and care – Karcher HDS 5-12 C User Manual

Page 23

background image

– 7

Lock in the steel pipe into the holder of

the appliance hood.

Roll up high pressure hose and electri-

cal conduit and hang them into the re-

spective holders.

Note: Do not twist high pressure hose and
electrical conduit.

Caution
Frost will destroy the not completely water
drained device.

Store in a frost free area.

If the device is connected to a chimney, the
following must be observed:
Caution
Threat of damage by penetrating cold air
through the chimney.

Disconnect device from chimney when
outside temperature drops below 0 °C.

If it is not possible to store frost free, shut
down device.

For longer work breaks or if a frost free stor-

age is not possible:

Drain water.

Flush device with anti-freeze agent.

Empty detergent tank.

Screw off water supply hose and high
pressure hose.

Screw off supply hose at boiler bottom

and drain heating spiral empty.

Operate device for max. 1 minute until
the pump and conduits are empty.

Note: Observe handling instructions of the
anti-freeze agent manufacturer.

Use commercially available anti-freeze
agent.

Switch on appliance (without heater) till

the appliance has been completely

rinsed.

A certain corrosion protection is achieved
with this as well.

Caution
Risk of injury and damage! Note the weight
of the appliance in case of storage.

Figure 7
Caution
Risk of damage! When loading the appli-
ance with a forklift, observe the illustration.
Caution
Risk of injury and damage! Observe the
weight of the appliance when you transport
it.

When transporting in vehicles, secure
the appliance according to the guide-
lines from slipping and tipping over.

ƽ

Danger

Risk of injury by inadvertent startup of ap-
pliance and electrical shock.
First pull out the plug from the mains before
carrying out any tasks on the machine.

Set the appliance switch to "0/OFF“.

Shut off water supply.

Open the hand spray gun.

Turn on pump shortly (appr. 5 seconds)
with device switch.

Pull main plug out of socket with dry
hands only.

Remove water connection.

Activate hand spray gun until device is
pressure less.

Lock the trigger gun.

Allow device to cool down.

Your Kärcher vender will inform you
about the performance of a periodic
safety inspection resp. signing of a
maintenance contract.

Storing the Appliance

Frost protection

Shutdown

Dump water

Flush device with anti-freeze agent

Storage

Transport

Maintenance and care

23

EN

This manual is related to the following products: