Troubleshooting – Karcher NT 75-1 Tact Me Te H User Manual
Page 25
– 8
Close the filter door, it must lock into
place.
Push both locking lugs of the filter cover
in with the screwdriver and tighten them
in a clockwise direction.
ƽ
Danger
The dust that has been collected should be
transported in dust-proof containers. No re-
filling is permitted. The waste containing
asbestos is to be disposed off according to
the rules and regulations for waste dispos-
al.
ƽ
Danger
Only persons trained in waste disposal are
permitted to dispose off the dust collection
container.
Illustration
Close the suction connection, see wet
vacuuming.
Release and remove the suction head.
Illustration
Pull over the safety filter sack.
Illustration
Pull out the safety sheet.
Close the safety filter sack using the
self-adhesive flap.
Pull the safety filter bag down and back-
wards from the filter nozzle.
Illustration
Close tightly the opening of the suction
connection of the safety filter sack using
the closing lid.
Illustration
Securely close the safety filter bag with
the attached cable tie.
Remove the safety filter bag.
Wipe the inside of the container using a
damp cloth.
Dispose of the safety filter bag in a dust-
tight bag according to the statutory pro-
visions.
Illustration
Affix a new safety filter bag.
Illustration
Place the safety filter bag over the con-
tainer and insert the interior paper filter
bag into the container in an L-shaped
fashion.
Insert and lock the suction head.
Release and remove the suction head.
Clean the electrodes with a brush.
Insert and lock the suction head.
ƽ
Danger
First pull out the plug from the mains before
carrying out any tasks on the machine.
Note: In case of a failure (e.g. filter break-
age) the appliance must be turned off im-
mediately. The failure must be remedied
before the appliance is put into operation
again.
Check the receptacle and the fuse of
the power supply.
Check the power cable, the power plug,
the electrodes and the receptacle of the
device.
Turn on the appliance.
Empty the container.
Turn off the appliance and wait for 5
seconds, turn it on again after 5 sec-
onds.
Clean the electrodes as well as the
space between the electrodes with a
brush.
Replacing the safety filter sack
Cleaning the electrodes
Troubleshooting
Suction turbine does not run
Suction turbine turns off
Suction turbine does not start again
after the container has been
emptied
25