Operation – Karcher NT 75-1 Tact Me Te H User Manual
Page 22
– 5
ṇ
Warning
The flat pleated filter must always be in
place while vacuuming.
–
If wet dirt is vacuumed with the uphol-
stery or crevice nozzle, or if water is
sucked up from a container, it is recom-
mended to deactivate the "automatic fil-
ter cleaning" function.
–
If the maximum liquid level is reached
the appliance will turn off automatically.
–
In case of non-conductive liquids
(such as emulsion drilling fluids,
oils, and greases) the appliance is
not turned off when the container is
full. The filling level must be continu-
ously monitored and the container
must be emptied in time.
–
After the wet vacuuming: Clean the flat
folded filter with the filter cleaning.
Clean the electrodes with a brush.
Clean the container with a damp rag
and dry it.
Illustration
The suction hose is equipped with a clip
system. All C-35/C-DN-35 accessories can
be connected.
Plug in the main plug.
Switch on the appliance at the rotating
knob.
Set the suction output (min - max) at the
rotary switch.
ƽ
Danger
Risk of injury and damage! The socket out-
let is only for the connection of power tools
to the vacuum cleaner. Any other use of the
socket outlet is not permitted.
Connect the mains plug of the electric
power tool to the vacuum cleaner.
Switch on the appliance at the rotating
knob.
Indicator lamp is on; vacuum cleaner is in
the standby mode.
Note: The vacuum cleaner is turned on and
off automatically with the electric power
tool.
Note: The vacuum cleaner starts automat-
ically within 0.5 seconds and continues to
run for 15 seconds after the power tool has
being switched off.
Note: Please refer to "Technical specifica-
tions" for the power connection specifica-
tions of the power tools.
Illustration
Adjust the stepped power tool adaptor
to fit the connection of the electric pow-
er tool.
Illustration
Remove the elbow from the suction
hose.
Attach the stepped power tool adaptor
to the suction hose.
Illustration
Connect the adaptor to the electric pow-
er tool.
Note: The different suction hose sections
are required to allow an adjustment to the
connection sections of the processing
tools.
Set the minimum volume flow for the
suction hose cross section at the rotary
switch.
The scale displays the suction hose cross
section.
General
Clip connection
Operation
Rotating knob
–
Appliance ON
–
Filter dedusting OFF
–
Appliance OFF
–
Appliance ON
–
Filter dedusting ON
Turning on the Appliance
Adjust the suction output
Working with electrical power tools
22