– 10
Technical specifications
Type
HD 10/16-4
Cage Ex
Power connection
Voltage
V
400
Current type
--
3~
Frequency
Hz
50
Connection output
kW
5,5
Mains fuse (slow-blow)
A
16
Maximum allowed net impedance
Ohm
(0,086+j0,054)
Water connection
Max. feed pressure
MPa (bar)
1 (10)
Max. feed temperature
°C
50
Min. feed volume
l/min (l/h)
16,7 (1000)
Inlet hose length (min.)
m
7,5
Inlet hose diameter (min.)
Inch
3/4
Performance data
Working pressure
MPa (bar)
16 (160)
Max. excess operating pressure (safety valve)
MPa (bar)
22,0 (220)
Flow rate
l/min (l/h)
16,7 (1000)
Nozzle size
--
60
Recoil force of trigger gun
N
35
Values determined as per EN 60355-2-79
Noise emission
Sound pressure level L
pA
dB(A)
71
Uncertainty K
pA
dB(A)
2
Sound power level L
WA
+ Uncertainty K
WA
dB(A)
87
Hand-arm vibration value
Hand spray gun
m/s
2
<2,5
Spray lance
m/s
2
<2,5
Uncertainty K
m/s
2
1
Fuel
Oil quantity - pump
l
2
Oil type - pipe
--
Hypoid SAE 90
(6.288-016.0)
Dimensions and weights
Length
mm
980
Width
mm
720
Height
mm
1100
Typical operating weight
kg
114
Miscellaneous
Ambient temperature
°C
+5...+40
Ignition protection class
Ex II G c T3
23