beautypg.com

Faults – Karcher HD 1050 De Cage User Manual

Page 23

background image

– 8

Note
Observe handling instructions of the anti-
freeze agent manufacturer.

Pump in conventional frost protection
agents through the appliance.

A certain corrosion protection is achieved
with this as well.

ƽ

Danger

Risk of injury if the machine is left running
in an unattended state. Remove the spark
plug before doing any work on the appli-
ance.
Risk of burns! Do not touch hot silencers,
cylinders or radiator ribs.

Follow operating instructions of the engine
manufacturer!

Safety thermostat at the high pressure
pump has switched off the appliance af-
ter long period of cycle operation.

Allow the appliance to cool down; then
restart it. Refer section "Interrupting op-
eration".

Operating speed of the engine is too low

Check operating speed of the engine
(refer to technical data).

Nozzle is set to "CHEM"

Set nozzle to "High pressure".

Nozzle is blocked/ washed out

Clean/ replace nozzle.

Sieve in the water connection is dirty

Clean sieve.

Air within the system

Appliance ventilation:

Amount of water supply is too low.

Check water supply level (refer to tech-
nical data).

Pipe inlets to pump are leaky or blocked

Check all inlet pipes to the pump.

Pump leaky

Note
3 drops/minute are allowed.

With stronger leak, have device
checked by customer service.

Inlet pipes to the pump are leaky.

Check all inlet pipes to the pump.

Air within the system

Appliance ventilation:

Nozzle is set to "High pressure"

Set nozzle to "CHEM".

Detergent suction hose with filter is
leaky or blocked

Check/ clean detergent suction hose
with filter.

Backflow valve in the connection of the
detergent suction hose is jammed

Clean/ replace backflow valve in the
connection of the detergent suction
hose.

Detergent dosing valve is closed or
leaky/ blocked

Open or check/clean detergent dosing
valve.

If malfunction can not be fixed, the de-
vice must be checked by customer ser-
vice.

Flush device with anti-freeze agent

Faults

Appliance is not running

With HD 801 Cage only:

Device is not building up pressure

Device leaks, water drips from the

bottom of the device

Pump is vibrating

Detergent is not getting sucked in

HD 1050 B, HD 1050 DE only:

23

EN

This manual is related to the following products: