Installation – AccuTemp ACCU-STEAM GAS GRIDDLE User Manual
Page 8

AT2T-3238-1 Rev. C
ACCU-STEAM GAS GRIDDLE OWNERS MANUAL
Page
4/29
INSTALLATION
This installation must conform with local codes, or in the absence of local codes, with
National Fuel Gas Code, ANSA/NFPA 54
, or the
Natural Gas and Propane
Installation Code, CSA B149.1
, as applicable.
The appliance and its individual shutoff must be disconnected from the
gas supply piping system during any pressure testing of that system at test
pressures in excess of ½ psi (3.5kPa)
The appliance must be isolated from the gas supply piping system by
closing its individual manual shut off valve during any testing of the gas
supply piping system at a test pressure equal to or less than ½ psi (3.5kPa).
LOCATION AND PLACEMENT
The AccuTemp
A
CCU
-S
TEAM
gas griddle can be placed on a commercial kitchen
counter-top or AccuTemp griddle stand.
The operating temperature ranges from 200°- 400°F (93°- 204°C). Since these
temperatures can also be found on surfaces around the perimeter of the griddle, care
should be given not to install griddle next to or against, objects or surfaces with a low
melting or flash point. See Figure 1 for clearance restrictions.
Figure 1
WARNING
Only qualified service technicians/electricians should perform the
installation to ensure that all electrical and safety requirements are met
and that all wiring is performed in accordance with all national, state and
local electrical codes.
CAUTION
Temperatures on and around the griddle cooking surface could cause
severe burns.
CLEARANCE RESTRICTIONS
COMBUSTIBLE
NON-COMBUSTIBLE
SIDES
1”
0”
REAR
2”
0”