Accu-steam gas griddle start-up form, Accutemp products, inc, Location: __________________ address – AccuTemp ACCU-STEAM GAS GRIDDLE User Manual
Page 39: Serial number ________ model number, Is the griddle level ? (circle one) yes / no, Is the grease pan installed (circle one) yes / no, 8415 north clinton park, Ft. wayne, in 46825, Phone: +1-260-469-0415 or 1-800-480-0415, Fax: +1-260-493-8914

ACCU-STEAM™ Gas Griddle Start-Up Form
AccuTemp Products, Inc.
Location: __________________ Address: ___________________________
City: _____________ State: _______ Zip: _________ Ph#______________
Serial Number ________ Model Number: ____________________________
Service Agency: ____________________ Technician: __________________
NOTE: AccuTemp Products, Inc. is not responsible for the installation and/or modifications
to the electrical or gas supply sources.
Is the 120 VAC wall receptacle position in a low heat zone. (circle one) Yes / No
(
Note: It is recommended that the wall receptacle be placed as low as State and Local codes allow.
Placement in high heat zones such as, just above, below or beside the exhaust flue, will cause service
issues that will not be covered under the product warranty
.)
Is an external regulator connected to the griddle? (circle one) Yes / No
( NOTE: An external regulator should not be used unless the supply gas pressure is more than 0.5 psig.)
Is the griddle being installed at an altitude greater than 4,000 feet? (circle one) Yes / No
( NOTE: If the altitude is greater than 4,000 feet above sea level, contact the AccuTemp Technical &
Customer Support Department to verify the correct orifice sizes for the pilot and main burners.)
If this is a table top installation, have the (4) rubber foot tips been installed ? (circle one) Yes / No
Is the griddle level ? (circle one) Yes / No
Is the grease pan installed (circle one) Yes / No
Is the griddle hard connected to the gas supply line? (circle one) Yes / No
If the griddle is connected with a flexible hose, is a restraining device used? (circle one) Yes / No
Gas Pressure Measurements:
Natural : _____ 5” WC (Regulator Valve – 1/8” NPT) _____ 3.5” WC (Pilot Regulator – 1/4" NPT)
Propane : _____ 10” WC (Regulator Valve – 1/8” NPT) _____ 8” WC (Pilot Regulator – 1/4" NPT)
Does the griddle operate properly when all gas appliances are operating? (circle one) Yes/No
Verify the actual surface temperature at a thermostat setting of 375° F ( _______° F)
(use a contact temperature probe instead of an infrared thermometer to measure the temperature)
I accept this Start-Up Form as complete and accurate:
___________________________________ Restaurant Management Date: ___/___/___
Note: This Start-Up Form must be completely filled out and faxed or mailed to the AccuTemp
Technical & Customer Support Department, before the warranty is activated.
AccuTemp Products, Inc
Attn: Technical & Customer Support Department
8415 North Clinton Park
Ft. Wayne, IN 46825
Phone: +1-260-469-0415 or 1-800-480-0415
Fax: +1-260-493-8914
FS3803-0607