Hot dog corral, Technical theory of operation – A.J. Antunes & Co HDC-50A 9300360 User Manual
Page 12
Hot Dog Corral
12
A.J. Antunes & Co.
P/N 1010609 Rev. I 03/12
teCHnICal tHeOry Of OperatIOn
Hot Dog Corral technical theory of
Operation
When the Rocker switch (Power On/Off) is ON, voltage
flows to the capillary bulb thermostat(s), Drive Motor
assembly, and to the Digital timer.
**
nOte: HDC-20 units consist of a single ther-
mostat that controls the entire grill area tem-
perature. HDC21a/30a/35a/50a units consist of
2 thermostats. the upper thermostat controls
the upper grill area temperature and the lower
thermostat controls the lower grill area tempera-
ture.
Provided that the grill area temperature is below the
thermostat setting, the thermostat calls for heat by
supplying line voltage to the Heating element.
nOte: the Heating element(s) are secured to the
under-side of the grill area.
as the grill area begins to heat up, the thermostat’s
bulb (mounted near the Heating element) monitors the
grill area temperature. Once the grill area temperature
approaches the thermostat setting, the thermostat’s
contacts open and the Heating element stops heating.
the heating circuit(s) will cycle on and off as needed,
even at idle. the hot dogs are placed between the
Roller Rods of the sliding Driver frame assembly. as
the Drive Motor runs, it operates a linkage system
which, in turn, operates the Driver frame assembly by
moving it up and down.
as the hot dogs roll, they absorb the heat from the grill
surface area.
nOte: the Driver frames used in HDC-20/30a/50a
units slide on four replaceable nylon Glides that
are pressed into the corners on the unit. the Driver
frames used in HDC-21a/35a units integrate four
replaceable nylon Glides with retainers. the glides
help prevent the Driver frame from scratching the
Grill area.
** the Digital timer is used only on some models.
the customer can program the timer up to 15 min-
utes. It is used to monitor the product cooking/
heating time. an integrated audio signal will sound
for a few seconds at the end of a timed cycle.
- HDC-50A 9300357 HDC-50A 9300356 HDC-50A 9300352 HDC-50A 9300351 HDC-50A 9300350 HDC-35A 9300344 HDC-35A 9300342 HDC-35A 9300341 HDC-35A 9300340 HDC-30A 9300336 HDC-30A 9300334 HDC-30A 9300332 HDC-30A 9300331 HDC-30A 9300330 HDC-21A 9300324 HDC-21A 9300322 HDC-21A 9300321 HDC-21A 9300320 HDC-20RC 9300309 HDC-20RC 9300308 HDC-20RC 9300306 HDC-20 9300380 HDC-20 9300304 HDC-20 9300302 HDC-20 9300300