beautypg.com

ROTHENBERGER Red Box User Manual

Page 16

background image

ENGLISH

12

5. Addition of further refrigerants

Whenever new refrigerants are available which are not yet included in the ROCOOL 600, they will

be provided for download on www.rothenberger.com free of charge.
Use

to start refrigerant upload. Choose the desired .txt. file and click „Write“ to write the new

refrigerant on the ROCOOL 600.

6. Recording

1. Repeatedly press SET (4) until the display of the ROCOOL 600 shows the sample rate (e.g. Sr30).

The number indicates the time interval in seconds between two samples.

2. Press Play / Pause (8) and REC (6) for 5 seconds until the recording parameters time, date and

year appear on the display of the ROCOOL 600.

3. After 5 seconds the displays changes back to the main screen.

4. Use the REC (6) button to change between record- and main screen.

5. The display of “Ext Mem“ or “Int Mem“ indicates whether data is stored on the external or

internal memory  whenever the Red Box is connected the data is stored on the external

memory. Whenever no Red Box is connected the data is stored on the internal memory.

6. Press Play / Pause (8) to stop recording  the hourglass indicates when the storage process is

completed.
7. Press Del (7) for 5 seconds to delete the internal or external memory. The delete process may

take a few minutes.  when the Red Box is connected the external memory gets deleted.

When no Red Box is connected the internal memory gets deleted.  In doing so all records

will be deleted off the respective memory!