ROTHENBERGER ROWELD D 4/15 Aero User Manual
Page 30
28
ENGLISH
Fault No.
Possible causes
Remedies
1
Smaller or too small a welding rod
diameter
Use larger welding rod diameter, if
necessary
2
Temperature sensor defective
1)
3
Temperature controller defective
1)
5
Cable connections defective
Check cable connections.
1)
8
Hot air temperature below start inter-
lock temperature
Allow hand extruder to heat up
9
Melt temperature below start interlock
temperature
Allow hand extruder to heat up
10
Preheat time for hot air too short
Allow hand extruder to heat up
11
Preheat time for melt too short
Allow hand extruder to heat up
13
Air supply not constant
1)
14
Wrong rated voltage
Rated voltage > permissible voltage
Check mains voltage
Rated voltage < permissible voltage
Check mains voltage
1)
15
Extension cable heats up
Unroll cable reel
Check cable cross-section (see also
section “Safety“)
16
Extruder nozzle plugged with foreign
matter
Clean extruder.
Extruder nozzle – left-hand thread
17
Drive unit defective
1)
18
Electronic control defective
1)
19
Controller programming error
1)
20
Welding rod feed
Remove welding rod
Observe instructions in section “Main-
tenance“!
Observe instructions for operation!
22
Hot air unit defective
1)
23
No mains voltage
Check voltage supply
1)
Consult ROTHENBERGER Werkzeuge GmbH