44

WARNING: When cleaning steam coil fins, be careful not to bend the fins. If fins are bent, straighten

by using a fin comb which is available from local air conditioning supply houses.

90 DAYS

1. Remove lint from around basket (tumbler), drive motors, and surrounding areas.

2. Remove lint from gas valve burner area with a dusting brush or vacuum cleaner attachment.

3. Clean any lint accumulation in and around both the blower and drive motor casing openings.

NOTE: To prevent damage, avoid cleaning and/or touching ignitor/flame-probe assembly.

EVERY 6 MONTHS

Inspect and remove lint accumulation in customer furnished exhaust ductwork system and from dryer’s internal
exhaust ducting.

NOTE: THE ACCUMULATION OF LINT IN THE EXHAUST DUCTWORK CAN

CREATE A POTENTIAL FIRE HAZARD.

NOTE: DO NOT OBSTRUCT THE FLOW OF COMBUSTION and VENTILATION AIR.

CHECK CUSTOMER FURNISHED BACK DRAFT DAMPERS IN THE EXHAUST
DUCTWORK. INSPECT and REMOVE ANY LINT ACCUMULATION, WHICH CAN
CAUSE THE DAMPER TO BIND or STICK.

NOTE: A back draft damper that is sticking partially closed can result in slow drying and shutdown of

heat circuit safety switches or thermostats.

NOTE: When cleaning the dryer cabinet(s), avoid using harsh abrasives. A product intended for the

cleaning of appliances is recommended.