beautypg.com

Programming options, Auto tach programming procedure – Autostart CT-3200 User Manual

Page 9

background image

CT-3200 Installation Guide

P. 9

Button

Ι

for Option

1,

Button

ΙΙ

for

Option

2,

Buttons

Ι & ΙΙ

for

Option

3.

Table 3

Programming Options

MODE 1

(* indicates default setting)

FUNCTION 1 – Ignition-controlled Door Locks

OPTION 1*

Ignition-controlled Door Locks

DISABLED

OPTION 2

Ignition-controlled Door Locks

ENABLED

OPTION 3

Ignition-controlled Door Locks

DISABLED

FUNCTION 2 – Secure Lock

OPTION 1*

Secure Lock

DISABLED

OPTION 2

Secure Lock

ENABLE

OPTION 3

Secure Lock

DISABLED (½ second disarm pulse)

FUNCTION 3 – Passive / Active Arming of the Starter Kill

OPTION 1*

Starter Kill

PASSIVE

(1-minute timeout.)

OPTION 2

Starter Kill

ACTIVE

OPTION 3

Starter Kill

PASSIVE

(3-minute timeout.)

FUNCTION 4 – Lock Pulse Duration

OPTION 1*

7/10-second

LOCK / UNLOCK

pulses

OPTION 2

4-second

LOCK / UNLOCK

pulses

OPTION 3

7/10-second

LOCK

pulse and two ¼-second

UNLOCK

pulses

FUNCTION 5 – Flashing LED

OPTION 1*

ENABLED

(without starter kill Æ will flash only when ignition is OFF)

OPTION 2

DISABLED

OPTION 3

ENABLED

(with starter kill Æ will flash when the starter kill engages.

This option should be selected ONLY if the starter kill is installed.)

MODE 2

(* indicates default setting)

FUNCTION 1 – Engine Run Time

OPTION 1

4-minute Run Time in Gas Mode / 9-minute in Diesel Mode.

OPTION 2* 15-minute Run Time in Gas Mode / 20-minute in Diesel Mode.
OPTION 3

25-minute Run Time in Gas Mode / 30-minute in Diesel Mode.

FUNCTION 2 – Idle Mode

OPTION 1

Idle Mode

DISABLED

OPTION 2*

Idle Mode

ENABLED

OPTION 3

Idle Mode

DISABLED

FUNCTION 3 – Engine Type – Gas or Diesel

OPTION 1

DIESEL

Engine Mode (in Cold Weather Mode Run time 20 min).

OPTION 2*

GASOLINE

Engine Mode

OPTION 3

DIESEL

Engine Mode

FUNCTION 4 – AUX 1 programming

OPTION 1

N/A

OPTION 2*

Panic mode (by pressing and holding the

Ι

key until horn honks)

OPTION 3

Horn confirmation when pressing

Ι

button

Auto Tach Programming Procedure

NOTE: If no tach has been programmed and the

ΙΙ

button is pressed, there will be no

start attempt and the vehicle will give 5 flashes. If another tach programming is required,
simply repeat the auto tach programming procedures. The module stores the tach
setting, being autotach or multi-speed tach, until the module is reset. Only if the