background image

6 Pin Power Connector

6-pin

Description

Test For Wire

1-Yellow

30amp Starter Output - This wire will test 0volts in off, accessory and in

the ignition position.12volts during start only.

2-Green

30amp Heat/Acc Output - This wire will test 0volts in the off position 12-

14volts in the accessory and run positions and 0 volts during start

3-Red

30amp Power Input - 12volts at ignition harness or from battery. Supplies

power for the ignition, selectable output and park light relays.

4-Red

30amp Power Input - 12volt power at ignition harness or from battery.

Supplies power for accessory and start relays

5-Blue

30amp Ignition Output - This wire will test 0volts in the off and accessory

position 12volts in the ignition, start and run.

6-White

30amp Select Output - Selectable output for 2nd Ign, acc or starter.

Auxiliary Connectors - 4, 11 and 14 pin Connectors

Pin Number

Function

Description

1-Yellow

Re-Arm Output- 0.75 second pulsed output when locked and on

remote start shutdown. Used for factory alarm re-arm.
Programmable output. See Menu 3

2-Red/Wht

Trunk Release Output (-) - Hold the unlock button for 3 seconds.

Output will stay on until the unlock button is released (Max 5 seconds)
Programmable to (-)Park lights. See Menu 2

3-Brown

Disarm Output (-) - 0.75sec pulsed output when unlocked and pulse

before remote start activation. Used for Factory Alarm Disarm.

4-Orange

Starter Kill and Negative While Running Output (-) - Active when

armed and/or during remote start.

Anti-Grind - Used for optional starter disable, and anti-grind relay.

Programmable output. See Menu 3

5-White/ Blue Siren Output (+) - Output to activate siren.

Programmable output See Menu 1&2

6-Black/White Park Brake Input (-) - Input to detect Park Brake Switch.

Connect switch that provides (-) when the switch is applied.

7-Purple

Door Pin Input (+) - Input to detect open door. Connect to door pin

that switches to 12volts when the door opened.

8-White

Park Lights Output (+) - +10amp park light output. Connect to circuit
0volts when Parking Lights are off, 12volts when park lights are on.

9-Green/White Hood Pin Input (-) - Negative input from hood pin safety switch.

Switch is grounded when the hood is opened. Must be connected.

10-Green

Door Pin Input (-) - Input to detect open door. Connect to door pin

that switches to Negative when the door is opened.