Maintenance
Your braising pan is designed to require minimum maintenance, but certain parts
may need replacement after prolonged use. After installation, no user adjustment
should be necessary. If a service need arises, only authorized personnel should
perform the work.
Service personnel should check the unit at least once a year. This periodic main-
tenance should include inspecting electrical wires and connections, cleaning the
inside of the control console, and possible adjustment of the pilot light. (Units with
standing pilot ignition only) At least twice a year, grease the two trunnion bearings
and worm gear.
We recommend the use of number two grade LGI lithium grease. Add grease through
the zerk fittings on the gear hosing until grease flows out of the bearings around trun-
nion shaft. Also, add grease in the gear to cover arc that is in contact with the worm
gear. Clean up excess grease.
A Service Log is provided with the warranty information at the back of this manual.
Each time service is performed on your equipment, enter the date on which the work
was done, what was done, and who did it. Keep the manual with the equipment for
quick and easy reference.
WARNING
DISCONNECT ELECTRICAL POWER FROM
THE UNIT BEFORE ATTEMPTING TO GREASE
THE TRUNNION BEARINGS.