Troubleshooting, Where to find more information – Allied Telesis AT-9900s Switches User Manual
Page 10

Removable Power Supply and Fan
10
Troubleshooting
If the PSU does not function as expected:
■
check that all cable connections are correct and secure.
■
check that the standby switch has been pressed and is in the On position
(DC models).
■
check that the PSU is receiving the correct AC voltage (AC models).
■
if LEDs indicate a PSU fault, replace the PSU or have your authorised
distributor or reseller service it.
Additional troubleshooting information is in the Hardware Reference for the
switch.
Where to Find More Information
■
The Hardware Reference for your switch provides detailed information on
the switch and its hardware features.
■
The Software Reference for your switch provides detailed information to
configure the switch and its software.
■
The Installation and Safety Guide for your switch describes how to install
your switch and includes statutory and safety information.
You can download these documents from
PSU 2
Green
PSU 2 is installed and supplying power to the switch.
The voltage output is within specification.
Red
PSU 2 is installed in the switch and has exceeded its
recommended temperature threshold of 75º C
(167º F), or the fan has failed.
A FOM is installed in the switch and has failed.
The bay is empty.
Off
A FOM is installed and operating at an acceptable
speed.
Table 2: PSU LEDs on the switch (Continued)