Allied Telesis AT-LXPWR/AC User Manual
Related documents, Verifying package contents, Installing the power supply

PN 613-50551-00 Rev. C
AT-LXPWR/AC Power Supply Installation Guide
Overview
The AT-LXPWR/AC Power Supply is designed for use in an
AT-LX3800U Multi-Service Transport System. The
AT-LXPWR/AC Power Supply shares the power load with the
preinstalled power supply and also powers the unit if the main
power supply fails. The power supply is hot swappable into and
out of the system.
An AT-LX3800U Multi-Service Transport System can contain
the following combinations of AC and DC power supplies:
One AC or one DC in either slot
One AC and one DC in either slot
Two AC or two DC
Related Documents
For details on the features and functions of your Allied Telesyn
AT-LX3800U Multi-Service Transport System, refer to the
following documents on our web site, www.alliedtelesyn.com:
AT-LX3800U Multi-Service Transport System Installation
and Maintenance Guide (part number 613-50549-00)
AT-S65 Management Software User’s Guide
(part number 613-50604-00)
Verifying Package Contents
Make sure that the correct components are included in your
package:
AT-LXPWR/AC Power Supply
Power cord retaining clip
AC power cord
This installation guide
AT-LX
PWRA
C
ON
100-240VAC
~
126
Warranty card
If any item is missing or damaged, contact your Allied Telesyn
sales representative for assistance.
Note
The AT-LX3800U chassis is shipped with one AT-LXPWR
power supply in the leftmost (PWR A) position.
Installing the Power Supply
To install an additional AT-LXPWR/AC power supply, perform
the following procedure:
1.
Remove the AT-LXPWR/AC unit from its shipping package
and store the package in a safe place. You must use the
original shipping package if you need to return the unit to
Allied Telesyn.
Note
You can install a DC power supply in the PWR A or PWR
B slot. The following procedure shows how to install it in
the PWR B slot. Follow the same installation process to
install a DC power supply in the PWR A slot.
2.
Locate the power cord retaining clip.
3.
Locate the retaining bracket on each side of the AC power
connector on the back of the power supply.
4.
With the “u” of the clip facing up, press the sides of the clip
toward the center and insert the short ends into the holes
in the retaining bracket.
131
ON
100-240VAC
~
179
Bracket
ON
100-240VAC
~
180
5.
Verify that the retaining clip is in the correct position.
6.
Use a Phillips head screwdriver to loosen the captive
screws on the blank cover on the right side (labeled PWR
B) of the back of the chassis and remove the cover.
Keep the blank cover in a safe area in case you need to
reinstall it later.
7.
Slide the power supply into the opening.
ON
100-240VAC
~
181
RX
PWR B
AT-LXPWRA
C
ON
12
RX
PWR B
AT-LXPWRA
C
ON
12
AT-LXPWRA
C
ON