beautypg.com

At-mcf2kfan fan module led, Troubleshooting the at-mcf2kfan fan module, Technical specifications – Allied Telesis AT-MCF2KFAN User Manual

Page 2: Electrical safety and emission statement

background image

AT-MCF2KFAN FAN Module LED

The fan module has one LED labeled STATUS. The states of the LED are
defined in this table.

Troubleshooting the AT-MCF2KFAN Fan Module

If the chassis is powered on but the fans in the AT-MCF2KFAN module are
not operating, either the fan module is not receiving power or the module has
failed. Try the following:

❑ Verify that the module is fully seated in the power supply/fan slot in the

chassis.

❑ Verify that the power cord to the power supply module in the chassis is

firmly connected to the power supply module and the power source.

❑ View the STATUS LED on the fan module. If the LED is amber, a fan has

failed and stopped. Replace the module.

❑ Try removing and reinstalling the fan module.
❑ Try replacing the fan module with either another fan module or a power

supply module. If the replacement module works, the problem is with the
original fan module. If the replacement module does not work, the problem
is with the chassis.

Note

For additional assistance, contact Allied Telesis Technical Support on our
web site at www.alliedtelesis.com.

State

Description

Green

The fans in the module are operating normally.

Amber

A fan has failed and stopped.

Technical Specifications

Dimensions (H x W x D)

4.1 x 13.3 x 20.6 cm

(1.6 x 5.25 x 8.1 in.)

Weight

818 g (1.8 lb.)

Input Voltage

12 volts and 3.3 volts

Maximum Power Consumption

8 watts

Operating Temperature:

0° C to 40° C

(32° F to 104° F)

Storage Temperature:

-20° C to 70° C

(-° 4F to 158° F)

Operating Humidity:

Less than 80%

noncondensing

Storage Humidity:

Less than 95%

noncondensing

Maximum Operating Altitude:

3,048 m (10,000 ft)

Maximum Nonoperating
Altitude:

4,000 m (13,000 ft)

Electrical Safety and Emission Statement

Standards: This product meets the following standards when installed in compliant host equipment.

RFI Emissions

FCC Class A, EN55022 Class A, EN61000-3-2, EN61000-3-3, VCCI Class A, C-TICK,

CE

WARNING:

In a domestic environment this product may cause radio interference in which

case the user may be required to take adequate measures.

EMC (Immunity)

EN55024

Electrical Safety

EN60950-1 (TUV), UL 60950-1 (

C

UL

US

)

Copyright

© 2006 Allied Telesis, Inc. All rights reserved.

No part of this publication may be reproduced without prior written permission from Allied Telesis, Inc.

U.S. Federal Communications Commission

Radiated Energy

Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant

to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful

interference when the equipment is operated in a commercial environment. This equipment generates, uses,

and can radiate radio frequency energy and, if not installed and used in accordance with this instruction

manual, may cause harmful interference to radio communications. Operation of this equipment in a residential

area is likely to cause harmful interference in which case the user will be required to correct the interference at

his own expense.

Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right

to operate this equipment.

Industry Canada

This Class A digital apparatus complies with Canadian ICES-003.

Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.

4

5

6