Overview
The AT-MCF2KFAN module is a cooling unit for the AT-MCF2000 series of
media converter chassis.
Figure 1. AT-MCF2KFAN Fan Module
Note
For a list of available chassis models in the AT-MCF2000 media
converter product line, contact your Allied Telesis sales representative or
visit our web site.
1123-a
AT-MCF2KF
AN
NORM
AL
FAULT
STATUS
Review the following before you begin to install the module in the chassis:
❑ Refer to the chassis’ Installation Guide to verify that the module is
appropriate for the unit.
❑ The AT-MCF2KFAN module draws its power from the backplane of the
chassis. It does not have a power cord.
❑ For instructions on how to remove a fan module, refer to the chassis’
Installation Guide.
❑ The AT-MCF2KFAN fan module is hot-swappable. You can install or
replace the module while the chassis is powered on.
❑ Refer to the chassis’ Installation Guide for a list of safety precautions to
observe when installing a module in the unit.
❑ The following procedure uses the AT-MCF2000 media converter chassis
for illustration purposes. Your chassis may be different.
Package Contents
Make sure the following items are included in the shipping package. If an item
is missing or damaged, contact your Allied Telesis sales representative for
assistance.
❑ One AT-MCF2KFAN fan module
❑ This Installation Guide
Installing the AT-MCF2KFAN Fan Module
To install the AT-MCF2KFAN fan module, perform the following procedure:
1. Remove the fan module from the shipping package.
Note
Store the packaging material in a safe location. You must use the original
shipping material if you need to return the unit to Allied Telesis.
2. Remove a blank panel from a power supply/fan module slot on the back
panel of the chassis by loosening the two captive screws on the panel with
a cross-head screwdriver. Refer to the chassis’ Installation Guide for the
location of the power supply/fan module slots.
Figure 2. Removing the Blank Panel from a Power Supply/Fan Module Slot
AT-MCF2KPNL2
1124-a
MANA
GEMEN
T
B
Note
Do not remove a blank panel from the chassis until you are ready to install
a module, especially if the device is powered on. An open slot allows dust
to enter the unit and impedes the ability of the chassis to maintain proper
airflow and cooling.
3. Slide the fan module into the slot as shown in Figure 3, until it is flush with
the back panel of the chassis. Light pressure may be needed to seat the
module on the connector on the back panel of the chassis.
Caution
Do not force the module into place. Doing so may damage the
connector pins on the backplane inside the chassis.
Figure 3. Installing the AT-MCF2KFAN Fan Module
4. Secure the fan module to the chassis by tightening the two captive screws
using a cross-head screwdriver. Refer to Figure 4.
Figure 4. Securing the AT-MCF2KFAN Fan Module
Note
If this is the initial installation of the chassis, refer to the chassis’
Installation Guide for instructions on how to install the remaining modules
in the unit.
1125-a
MAN
AGEM
ENT
B
AT-MCF2KF
AN
NORMAL
FAULT
STATU
S
1125-b
AT-MCF2KF
AN
NORM
AL
FAULT
STATUS
MAN
AGEMENT
B
AT-MCF2KFAN Fan Module
Installation Guide
Allied Telesis, Inc.
www.alliedtelesis.com
613-000585 Rev A
1
*613-000585 RevA*
2
3