beautypg.com

Troubleshooting, Acorn controls, Sv16 installation & operation manual – Acorn SV16 VALVE User Manual

Page 7

background image

Page 7 of 8

Acorn Controls

Division of Acorn Engineering Company

®

, A member of Morris Group International

Manual #7802-116-000

Date: 07/10/14

TROUBLESHOOTING:

CAUSE

SOLUTION

PROBLEM

1. SET POINT DIFFICULT TO SET OR

CANNOT BE REACHED

SUPPLY TEMPS NOT WITHIN
SPECIFIED LIMITS

HOT AND COLD SUPPLIES ARE
REVERSED

CHECK DIFFERENTIAL TEMPERATURE
BETWEEN SUPPLIES AND OUTLET

REINSTALL VALVE WITH SUPPLIES
CONNECTED TO MARKED INLETS

2. DOES NOT MAINTAIN OUTLET

TEMPERATURE OR CHANGES

FLUCUATION IN SUPPLY
PRESSURES

FILTERS BLOCKED WITH DEBRIS

CHECK DIFFERENTIAL TEMPERATURE
BETWEEN SUPPLIES AND OUTLET

CLEAN FILTERS

OVER TIME

3. DISCHARGE TEMPERATURE TOO

HOT OR TOO COLD

VALVE NOT ADJUSTED PROPERLY

READJUST VALVE TEMPERATURE PER
INSTALLATION INSTRUCTIONS

4. NO FLOW FROM VALVE

HOT OR COLD SUPPLY FAILURE
OR SHUTOFFS CLOSED

OPEN SHUTOFFS OR RESTORE HOT
AND COLD SUPPLIES

CHECK FILTERS BLOCKED WITH
DEBRIS

CLEAN FILTERS

HOT

WATER

SUPPLY

COLD

WATER

SUPPLY

HOT

WATER

SUPPLY

COLD

WATER

SUPPLY

SV16 SHOWER

VALVE

SHOWERHEAD

TUB SPOUT

SV16 SHOWER

VALVE

DIVERTER

VALVE

SHOWERHEAD

HANDHELD SUPPLY
CONNECTION

HANDHELD
SHOWER

TYPICAL PIPING w/ TUB SPOUT

TYPICAL PIPING w/ HANDHEALD SHOWER

SV16 Installation & Operation Manual