Thoroughly read all installation instructions and 
product safety information before beginning the 
installation of this product. 
FAILURE TO READ AND FOLLOW PROPER 
INSTALLATION AND MAINTENANCE 
INSTRUCTIONS MAY RESULT IN PRODUCT 
FAILURE WHICH CAN CAUSE PROPERTY 
DAMAGE, PERSONAL INJURY AND/OR 
DEATH.
Acorn Controls is not responsible for damages 
resulting from improper installation and/or 
maintenance. Installation of this valve shall be in 
accordance with Uniform Plumbing Code.
TO ENSURE ACCURATE AND RELIABLE 
OPERATION OF THIS PRODUCT, IT IS 
ESSENTIAL TO:
Ÿ
Properly design the system to minimize 
pressure and temperature variations.
Ÿ
Implement an annual maintenance program to 
ensure proper operation and temperature 
setting of valve(s).
Ÿ
This valve is factory preset, however it can be 
adjusted. It is the responsibility of the installer 
and or facility maintenance personal to make 
sure valve outlet temperature does not exceed 
115°F (46°C) after installation, maintenance or 
repair.
(Not provided by Acorn)
1. Wall anchors, screws, nuts and washers as
required.
2. Teflon tape for sealing water connections.
3. Allen wrenches for lever handle and bonnet set 
screws.
4. Copper pipe adapters as required.
5. Snap-ring pliers with pins less than 0.03”
Ÿ
Flush supply lines of all foreign material such 
as pipe dope, chips or solder prior to 
connecting to mixing valve.
Ÿ
To ensure proper installation review the 
manual thoroughly to verify rough-ins before 
beginning any work.
Ÿ
Installation and field adjustment are the 
responsibility of the installer.
Ÿ
Maximum water pressure is 125 psi (8.62 
bars). Maximum inlet hot water temperature is 
180°F (82°C). Temperature adjustment range 
is 85-115°F (29-46°C). Valve assembly must 
be drained prior to being subjected to freezing 
temperatures. Valve includes integral checks 
stops.
PRESSURE
DROP
10
(69)
1.9
(7.1)
15
(103)
2.3
(8.7)
20
(138)
2.7
(10)
30
(207)
3.3
(12.4)
45
(310)
4
(15.1)
60
(414)
4.6
(17.5)
5
(34)
1.3
(5)
FLOW RATE
GPM (LPM)
PSID (KPA)
CV
0.6