Ampro Corporation COREMODULE PCI-104 User Manual
Page 29

Appendix B
I/O Interface Board
CoreModule 800
QuickStart Guide
25
J4
Pin #
Signal
Pin # On-
board
Description
14
RTS1*
J7-16
Request To Send 1 – Indicates serial port is ready to transmit data. Used
as hardware handshake with CTS1 for low level flow control.
15
TXD1
(through
JP1)
J7-12
Transmit Data 1 Output – This line is typically held to a logic 1 when
no data is being sent. A logic 0 (On) must be present on RTS1, CTS1,
DSR1, and DTR1 before transmitting data on this line.
16
CTS1*
J7-17
Clear To Send 1 – Indicates external serial device is ready to receive
data. Used as hardware handshake with RTS1 for low level flow
control.
17
DTR1*
J7-13
Data Terminal Ready 1 – Indicates port is powered, initialized, and
ready. Used as hardware handshake with DSR1 for overall readiness to
communicate.
18
RI1*
J7-18
Ring Indicator 1 – Indicates external serial device is detecting a ring
condition. Used by software to initiate operations to answer and open
the communications channel.
19
GND
J7-14
Digital Ground
20
S1_TXD
JP1-3
Serial Port 2 Transmit TTL – Places TTL TX signals on pin 3 of the
Serial Port 2 (J4) when jumper (JP1) on I/O Board is set to pins 2-3.
21
USBOC0
J4-21
USB 0 Over Current – The Power Distribution Switch (U1) monitors
power and disables port if this input is low.
22
USB Pwr
J4-22
USB Port 0 power (+5V +/-5%)
23
USBP0-
J4-23
Universal Serial Bus Port 0 Data Negative
24
USBP0+
J4-24
Universal Serial Bus Port 0 Data Positive
25
GND
J4-25
USB Ground
26
USBOC1
J4-26
USB 1 Over Current – The Power Distribution Switch (U1) monitors
power and disables port if this input is low.
27
USB Pwr
J4-27
USB Port 0 power (+5V +/-5%)
28
USBP1-
J4-28
Universal Serial Bus Port 1 Data Negative
29
USBP1+
J4-29
Universal Serial Bus Port 1 Data Positive
30
GND
J4-30
USB Ground
31
MSDT
J4-31
Mouse Data
32
MSCK
J4-32
Mouse Clock
33
GND
J4-33
Ground
34
MSPwr
J4-34
Mouse Power (+5V +/-5%)
35
HDDAct
D1-1
IDE Hard Disk Drive Activity – IDE activity signal to HDD Activity
LED (D1).
36
ExtSMI*
J6-2
External SMI – Provides external SMI signal to the CoreModule 800.
37
ThermDP U3-3
Thermal Data Positive – Thermal data positive received from CPU.
38
BatLow*
J6-3
Battery Low –
39
ThermDN U3-4
Thermal Data Negative – Thermal data negative received from CPU.
40
NC
J4-40
Not Connected (External –5V input)
Notes: The shaded area denotes power or ground. The signals marked with * = Negative true logic.
NC = Not Connected at CoreModule 800.