24 Audio Authority AVAtrix User Manual
Audio Authority AVAtrix User Manual 25
Transfer Rate
9600 bps
Data Bits
8
Stop Bits
1
Parity
None
Flow Control or
Data Flow
None
Character type
ASCII
Abbreviated Command Examples
The general format of commands is as follows:
Definition of output(s) to be acted upon (Zone, Group, Main, All
Address letter of output (row), when selecting Cat 5 output
Cat 5 output port number (column), when selecting Cat 5 outputs
Source number to be routed to the output(s)
ZC23
Example 1. To route source input 3 to the main AVAtrix output, send the following command:
M3
(The AVAtrix selects source 3 to its main output)
Example 2. To change the source assigned to an individual zone, enter “Z” followed by the letter of the row,
followed by the number of the column (zone number) from 1 to 6, followed by the number of the source input
from 1 to 6. To assign source input 5 to the 2nd Cat 5 zone on the “C” row (second 1176 expander), send the
code:
ZC25 (Source 5 is selected to zone C2)
Example 3. To assign the same input source to all the zones, send the following command:
X4
(All Cat 5 zones output source 4)
Example 4. To change the source to an entire zone group, enter “Z” followed by the group number, followed
by the desired source input number. To assign source 3 to group 2, enter the code:
G23
(All zones in group 2 play Source 3)
NOTE: If zone groups have not been assigned, no action results from this command.
Query Commands and Responses
Retrieve the status of any part of the AVAtrix system using the query commands. A query command sent by
the controller will elicit a response according to the following table.
Command
Name
Response
Variables
?P or ?R
Screen Mode
P if display is in professional screen
R if display is in residential screen
S if display is in any other screen (e.g. Setup)
?V
Panel Controls
– if panel controls are unlocked
+ if panel controls are locked
?W
Panel IR Receiver
– if IR receiver is unlocked
+ if IR receiver is locked out
?M
Main Output
Number of selected source
?Zwx
Cat 5 Output
Number of source selected by wallplate/receiver wx
w = Row A-L (AVX-562 Cat 5 array or 1176)
x = Column 1-6 (output number)