Campbell Scientific TD Operating System Addendum for CR510, CR10X, and CR23X User Manual
Page 39

TD ADDENDUM—SECTION 8. PROCESSING AND PROGRAM CONTROL EXAMPLES
AD-8-9
Loop 6, Output every 10 minutes until stopped
by user
17:
P87
Beginning of Loop
01:
60
Delay
02:
0
Loop Count
18:
P86
Do
01:
1
Call Subroutine 1
19:
P91
If Flag/Port
01:
21
Do if flag 1 is low
02:
31
Exit Loop if true
20:
P95
End
21:
P
End Table 1
*
3
Table 3 Subroutines
01:
P85
Beginning of Subroutine
01:
1
Subroutine Number
02:
P6
Full Bridge
01:
1
Rep
02:
22
7.5 mV 60 Hz rejection Range
03:
1
IN Chan
04:
1
Excite all reps w/EXchan 1
05: 1500
mV Excitation
06:
1
Loc [:LEVEL_FT ]
07:
.46199 Mult
08:
102
Offset
03:
P84
Data Table
01:
0
Seconds into interval
02:
0
Every time
03:
0
Records (0=auto; -=redirect)
04:
P70
Sample
01:
1
Reps
02:
1
Loc LEVEL_FT
05:
P95
End
06:
P
End Table 3