Appendix a. setting the station id – Campbell Scientific RF310, RF312, RF313 Narrowband Radios User Manual
Page 45
A-1
Appendix A. Setting the Station ID
Each RF310M, including the one in the RF base station, must have a unique Station ID.
Each RF modem has nine dip switches; the first eight must be set for a particular Station
ID. Following is a list of all possible Station IDs with the corresponding setting of the dip
switches. Here, 1 represents open, 0 is closed, and X is "don't care."
SWITCHES
SWITCHES
SWITCHES
ID
1234
56789
ID
1234
56789
ID
1234
56789
43
1101
0100X
86
0110
1010X
1
1000
0000X
44
0011
0100X
87
1110
1010X
2
0100
0000X
45
1011
0100X
88
0001
1010X
3
1100
0000X
46
0111
0100X
89
1001
1010X
4
0010
0000X
47
1111
0100X
90
0101
1010X
5
1010
0000X
48
0000
1100X
91
1101
1010X
6
0110
0000X
49
1000
1100X
92
0011
1010X
7
1110
0000X
50
0100
1100X
93
1011
1010X
8
0001
0000X
51
1100
1100X
94
0111
1010X
9
1001
0000X
52
0010
1100X
95
1111
1010X
10
0101
0000X
53
1010
1100X
96
0000
0110X
11
1101
0000X
54
0110
1100X
97
1000
0110X
12
0011
0000X
55
1110
1100X
98
0100
0110X
13
1011
0000X
56
0001
1100X
99
1100
0110X
14
0111
0000X
57
1001
1100X
100
0010
0110X
15
1111
0000X
58
0101
1100X
101
1010
0110X
16
0000
1000X
59
1101
1100X
102
0110
0110X
17
1000
1000X
60
0011
1100X
103
1110
0110X
18
0100
1000X
61
1011
1100X
104
0001
0110X
19
1100
1000X
62
0111
1100X
105
1001
0110X
20
0010
1000X
63
1111
1100X
106
0101
0110X
- 014A Met One Wind Speed Sensor (36 pages)
- 020C Wind Direction Sensor (26 pages)
- 024A-L Met One Wind Direction Sensor (30 pages)
- 03001-L R.M. Young Wind Sentry Set (34 pages)
- 03002, 03101, and 03301 R. M. Young Wind Sentry Sensors (40 pages)
- 034A-L WindSet (16 pages)
- 034B-L Met One Windset (34 pages)
- 036, 038 Spark Gapped Junction Box (6 pages)
- 05103, 05103-45, 05106, and 05305 R. M. Young Wind Monitors (30 pages)
- 083E Relative Humidity and Temperature Sensor (22 pages)
- 0871LH1 Freezing Rain Sensor (31 pages)
- 092 Barometric Pressure Sensor (24 pages)
- 10164-L Water Sampler Control Cable for use with Isco and Sigma Autosamplers (18 pages)
- 107-L Temperature Probe (28 pages)
- 108-LC Temperature Probe for MetData1 (12 pages)
- 108-L Temperature Probe (30 pages)
- 109-L Temperature Probe (30 pages)
- 109SS Temperature Probe (32 pages)
- 110PV Surface Temperature Probe (32 pages)
- 21108 RF450 Demo Kit (14 pages)
- 223-L Delmhorst Cylindrical Soil Moisture Block (28 pages)
- 227-L Delmhorst Cylindrical Soil Moisture Block (24 pages)
- 229 Water Matric Potential Sensor and CE4/CE8 (34 pages)
- 237-L Leaf Wetness Sensor (14 pages)
- 247-L Conductivity and Temperature (18 pages)
- 253-L and 257-L (Watermark 200) Soil Matric Potential Sensors (36 pages)
- 25458 DIN-Rail Terminal Kit (10 pages)
- 255-100 Novalynx Analog Output Evaporation Gauge (16 pages)
- 260-953 Alter-Type Wind Screen for Tipping Bucket Rain Gages (14 pages)
- 27106T Gill Propeller Anemometer (18 pages)
- 30066 Battery Terminal Bus (1 page)
- 380, 385, 380M, 385M Met One Rain Gages (22 pages)
- 3WHB10K 3-Wire Half-Bridge Terminal Input Module (14 pages)
- 43347 RTD Temperature Probe and 43502 Aspirated Radiation Shield (40 pages)
- 4386 Battery Terminal Bus (1 page)
- 4WFB120, 4WFB350, 4WFB1K 4-Wire Full Bridge Terminal Input Module (22 pages)
- 4WFBS120, 4WFBS350, 4WFBS1K 4 Wire Full Bridge Terminal Input Modules (46 pages)
- 4WPB100, 4WPB1K PRT Terminal Input Modules (16 pages)
- 52202 Electrically Heated Rain and Snow Gage (16 pages)
- 9522B Iridium Satellite Modem and COM9522B Interface Modem (46 pages)
- A100LK Anemometer (18 pages)
- A150 Desiccated Case (12 pages)
- A21REL-12 Relay Driver (10 pages)
- A6REL-12 Relay Driver (12 pages)
- AL200 ALERT2 Encoder, Modulator, and Sensor Interface (44 pages)